Mounting the SVP
The SVP has a depth of 14.5 inches (369 mm), while the 4U CBL controller
and dense intermix driv
e tray (DB60) have a depth of 34.1 inches (865 mm)
and 33.9 inches (860 mm), respectively.
if the SVP is rack-mounted between a CBL and dense intermix drive tray, as
shown below, there will not be enough space to access rear I/O panel of the
SVP.
T
o ensure that the SVP can be accessed for maintenance:
Locate the SVP at the top of the rack or above the system.
If a small form factor drive tray (DBS) or dense intermix drive tray (DB60)
is added at the top of the rack, prepare a 1U space between the system
and the small form factor, large form factor, and dense intermix drive
trays.
24 Installing the SVP
Hitachi Virtual Storage Platform G200, G400, G600 Service Processor Technical Reference