EasyManua.ls Logo

Hitachi G200 - Fibre Channel Cables

Hitachi G200
148 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Fibre Channel cables
When constructing a system with the direct connection or Fibre Channel switch
connection, consider the following:
If you connect a storage system to a FC host adapter through a switch, set Fabric = ON
and set to Point-to-Point.
If you connect a stor
age system directly to FC host adapter with the following fabric
topology:
For 2, 4 or 8 Gbps, set the storage port to
Fabric = OFF and Connection Type FC-AL
(Fibr
e Channel Arbitrated Loop).
For 16 or 32 Gbps, set the storage port to
Fabric = OFF and Connection Type P-to-P
(Point-to-Point).
For the 8-Gbps Fibr
e Channel ports, the combinations between data-transfer speeds
and connection types are as follows:
Connection
type
Data transfer speeds for 8-Gbps ports
2 Gbps 4 Gbps 8 Gbps Auto
FC-AL Available Available Available Available
(default)
P-to-P Available Available Available Available
Fabric Available Available Available Available
For the 16-Gbps Fibre Channel ports and for 16-Gbps SFP added to the 4- port FC 32-
Gbps package, the combinations between data-tr
ansfer speeds and connection types
are as follows:
Connecti
on type
Data transfer speeds for 16-Gbps ports/SFPs
2 Gbps 4 Gbps 8 Gbps 16 Gbps 32 Gbps Auto
FC-AL No
available
Available Available Not
available
Not
available
Available
1
P-to-P No
available
Available Available Available Not
available
Available
(default
2
)
Fabric Available Available Available Available Not
available
Available
Notes:
1. If this combination is specied, the maximum tr
ansfer speed automatically
specied is 8 Gbps.
2. If this default value is set, Fabric is set to ON automatically.
Fibre Channel cables
Appendix F: Data and power cables
Hitachi Virtual Storage Platform G200 Hardware Reference Guide 104