EasyManua.ls Logo

Hitachi G200 - CBSS Front Panel Leds (Without Bezel)

Hitachi G200
148 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Number Item Description
3 WARNING
LED O: Normal operation.
Amber: Component
requires maintenance.
Blink: Failure requires
maintenance.
Note: When System Option
Mode 1097 is set to ON,
the WARNING LED does not
blink, even if the following
failure service information
messages (SIM) are issued:
452xxx, 462xxx, 3077xx,
4100xx, and 410100.
LED might turn o during
user maintenance.
4 ALARM LED O: Normal operation.
Red: Processor failure
(system might be down).
Go to the Customer
Contact Us page at
https://
support.hds.com/en_us/
contact-us.html.
5 POWER ON/OFF (main
switch)
Powers the storage system.
6 Lock Locks and unlocks the front
panel be
zel by using the
supplied key.
Note: Remo
ving a controller can cause the POWER, READY, WARNING, and
ALARM LEDs on the front panel to turn o. These LEDs return to their on state
after the storage system recovers from the controller replacement.
CBSS front panel LEDs (without bezel)
The follo
wing table describes the denitions of the CBSS controller front panel LEDs.
CBSS front panel LEDs (without bezel)
Chapter 2: Virtual Storage Platform G200 controllers
Hitachi Virtual Storage Platform G200 Hardware Reference Guide 22