Number Item Description
8 LAN port Maintenance LAN port
(left) and user LAN port
(right).
9 Uninterruptible power supply (UPS)
port
N/A
10 ALARM LED (for cache ash
memory)
Red: Cache ash
memory can be
r
emoved.
11 Backup module N/A
12
STATUS
Green: Charging of the
battery in the backup
module is complete.
Blink green: Battery in
the backup module is
charging or
discharging.
Red: Backup module
can be removed.
Blink red: Backup
module can be
removed.
Blink red one time:
Battery failure
O: battery is not
installed, failure
occurred, or rmware
is being upgraded.
13 SAS port N/A
14 Port LED Blue: Port link is
established.
15 Power supply unit N/A
CBSS/CBSL AC power supply unit LEDs and connectors
The following table describes the denitions of the CBSS and CBSL AC power supply unit
LEDs and connectors.
CBSS/CBSL AC power supply unit LEDs and connectors