Appendix C: Environmental specifications for
VSP G200
The environmental speciî ´cations are described for the storage system.
Environmental specifications
Temperature
Caution: The follo
wing VSP Gx00/Fx00 storage system components are not
supported in high-temperature environments. Do not operate the following
components at temperatures of 40°C or higher:
â–
DB60 dense drive tray
â–
HDS provided service processor (SVP) server
â–
First-generation FMDs (non-DC2 FMDs)
State Controller
SFF, LFF drive
trays Dense intermix drive tray
Operating 50°F to 104°F
(10°C to 40°C)
50°F to 104°F
(10°C to 40°C)
50°F to 95°F (10°C to 35°C)
Non-operating 14°F to 122°F
(-10°C to 50°C)
14°F to 122°F
(-10°C to 50°C)
14°F to 122°F (-10°C to 50°C)
Transport,
stor
age
-22°F to 140°F
(-30°C to 60°C)
-22°F to 140°F
(-30°C to 60°C)
-22°F to 140°F (-30°C to 60°C)
Temperature
change rate
(°C/h)
10 or less
State Controller FMD drive trays
Operating 50°F to 104°F
(10°C to 40°C)
DKC-F710I-1R6FM or DKC-F710I-3R2FM drive is
installed: 50°F to 95°F (10°C to 35°C)
Appendix C: Environmental speciî ´cations for VSP G200
Hitachi Virtual Storage Platform G200 Hardware Reference Guide 88