EasyManua.ls Logo

Hitachi G200 - SSB2 Error Codes When SSB1 = 2 E31;B901;B90 A;B90 B;B912;D004

Hitachi G200
252 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
• SSB2 error codes when SSB1 = 2E31/B901/B90A/B90B/B912/D004 on
page 10-7
• SSB2=B992 error codes when SSB1 = B901 or B90A on page 10-16
SSB2 error codes when SSB1 = 2E31/B901/B90A/B90B/B912/D004
Error code
(SSB2)
Description
4A96 The pair cannot be created because the specified P-VOL belongs to a different CLPR
than the registered consistency group CLPR.
9100 The command cannot be executed because the user authentication is not performed.
B920 The pair cannot be created because the system identifier is not correct (left-most
number in the 6-digit serial number).
B923 The consistency group paircreate or pairresync was rejected because supported and
unsupported software is used in the DKC.
B927 You cannot run the following operations to a pair in a 2DC configuration:
Swap Suspend
Takeover
B928 The pair cannot be created because the Mirror ID is invalid.
B929 The pair operation was rejected because the firmware is being replaced.
B92A The pair cannot be created because the specified volume is a command device.
B934 The pair cannot be created because TC is not installed.
B935 S-VOL hide mode is not supported.
B936 The required shared memory for operating TrueCopy is not installed.
B93B The specified volume is a P-VOL. The pair cannot be released because the P-VOL is
specified as an S-VOL.
B941 The specified volume is an S-VOL. The pair cannot be released because the S-VOL is
specified as a P-VOL.
B945 The command was rejected because the volume is unpaired.
B952 The specified LU is not defined. The DKC configuration might have been changed.
Restart CCI.
B97B The operation cannot run because pair status is either PSUS (by user) or PSUE (because
of failure).
B97C The command was rejected because the volume is unpaired.
B990 The pair cannot be created because the consistency group ID is greater than is allowed.
If this error occurred when you did not specify the consistency group ID, contact Hitachi
Data Systems customer support (see Getting help on page xiv).
B992
(SSB1=B901)
The pair cannot be created because the DKC type does not support TrueCopy
Asynchronous.
B992
(SSB1=B90A)
The consistency group information cannot be acquired because TrueCopy or Universal
Replicator is not installed.
Troubleshooting
10-7
Hitachi TrueCopy® User Guide for Hitachi Virtual Storage Platform Gx00 and Fx00 Models

Table of Contents

Other manuals for Hitachi G200