Note: Check the target battery only. Do not touch other batteries.
3. Remove the front bezel.
4. Remove the BKMF in which the target battery is installed:
a. Check that the red STATUS LED on the BKMF is blinking.
b. Loosen the blue screw securing the BKMF on which the red STATUS
LED is blinking.
c. Close the lever and pull out the BKMF to remove it.
5. Check the connection of the battery cables:
a. Loosen the blue screw on the back of the BKMF.
b. Slide the top panel of the BKMF to remove the panel
126 Replacing a battery