Item Specification
RAID6: 6D+2P, 12D+2P, 14D+2P
Maximum number of parity groups 480
Maximum volume size 3 TB (when using the LDEVs of other
Stor
age Systems: 4TB)
Maximum volumes/host groups and iSCSI
targets
2048
Maximum volumes/parity groups 2048
*
A stor
age system congured with RAID6, RAID 5, or RAID 1 provides redundancy and
enhances data reliability. However, there is still a possibility of losing data caused by
unforeseeable hardware or software failure. Users should always follow recommended
best practices and back up all data.
Internal logic specications (CBL)
Item Specification
Control memory Flash memory: 32 MB
L3 cache memory: 4 MB
SDRAM: 1 GB
Data assurance method Data bus: Parity
Cache memory: EC
C (1 bit correction, 2 bit
detection)
Drive: Data assurance code
VSP G900 mechanical specications
Appendix B: System Specications
Hitachi Virtual Storage Platform G900 Hardware Reference Guide 70