EasyManua.ls Logo

Hitachi Highly WHP13300PSDPC8FQ - Installation, Vibration, and Tube Design

Hitachi Highly WHP13300PSDPC8FQ
33 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
HEAT PUMP WATER HEATER COMPRESSOR CRITERIA
热泵热水器专用压缩机使用基准 PAGE:10/31
18 Purge parts with dry nitrogen or dry air to remove remains in parts (dust, detergent, etc.)
bef
ore assembly of system. Time fur purging: over one second for pipe; over three seconds
for heat exchanger. Purging pressure: 0.9±0.1MpaG. Dew point of dry air: Below 20℃.
The motor winding temperature should be less than 149℃and hermetic terminal body
temperature should be less than 177℃in process of manufacturing.
19 Apply for vehicle
The
compressor should not be used on moving equipment such as automobiles,trains,ships, etc.
20 Installation
The
rotational axis of compressor should be kept vertical during operation. But in actual
application the axis incline must be within 5°at all directions during operation.
21
Pipe vibration
The displacement of t
he pipes, which connect from the compressor to other parts of the
refrigerate-or systems, should be less than 0.8mm(1/32)when the compressor is operating at
allowable rotational speed range and voltage range of rated ±10%.
Displacement in excess of 0.8mm(1/32) will require changing tube length and/or routing.
22 Connecting tube design
In designing and routing tubing that connect from the comprssor to the other parts of the air
conditioner, following should be considered.

Related product manuals