13
When you disable a remote operation, always use
the method used when in enabling. If you enabled it
with the method (2) or (3), for example, you cannot
disable it with the method (1).
You can stop the remotely started A even
by pressing the STOP button on the As in-
strument panel.
As an optional function, you can externally output the
remote operation setting signal.
3. HOW TO OPERATE [Setting of the Control Functions]
IMPORTANT
3.4.3 Enabling the Remote Operation
The following 3 methods (1), (2), and (3) are avail-
able to enable the remote operation. Usually em-
ploy the method (1).
Method (1): On the As Instrument Panel
a Connect the power.
b Hold down the RESET button and press the
ECOMODE button.
c Make sure that the REMOTE light is on to indi-
cate a remote operation enabled.
d To disable the remote operation, hold down the
RESET button and press the ECOMODE button.
Make sure that the REMOTE light is off to indi-
cate a remote operation disabled or a local opera-
tion enabled.
Method (2): On the Starter
q Disconnect the power.
w Remove the starter/control box cover.
e Connect the wires between the As starter/
control box and an external control panel. For in-
formation on a wiring diagram, see pages 40
through 43.
r Place the No. 4 pin of the DIP switch SW1 (on the
printed circuit board) in an on position.
t Return the starter/control box cover to its original
place.
y Reconnect the power.
u Make sure that the REMOTE light is on to indi-
cate a remote operation enabled.
With this method, usually, you may intend to permanently
use a remote operation. If you want to disable it for some
reason, you need to place the No. 4 pin of the DIP switch
SW1 in an off position.
Method (3): On an External Setting Switch
q Disconnect the power.
w Remove the starter/control box cover.
e Connect the wires:
between the As starter/control box and an
external control panel, and
between the As starter/control box and the
external setting switch.
For information on a wiring diagram, see pages 40
through 43.
r Make sure that the No. 4 pin of the DIP switch
SW1 (on the printed circuit board) is in an off posi-
tion.
t Return the starter/control box cover to its original
place.
y Reconnect the power.
u Turn on the external setting switch.
i Make sure that the REMOTE light flashes to indi-
cate a remote operation enabled.
o To disable the remote operation, turn off the ex-
ternal setting switch. Make sure that the REMOTE
light is off to indicate a remote operation disabled
or a local operation enabled.
IMPORTANT
AUTOSTART
起動待ち
REMOTE
遠 方
RUNNINGMODE
(1) To enable the remote operation
on the A’s instrument panel:
Hold down the RESET button
and press the ECOMODE button.
ECOMODE
エコモド
RESET
リセット
b
Action of
REMOTE Light
ON (not flashing)
ON (not flashing)
ON (flashing)
OFF
Enabled
Disabled
Method (1):
on the instrument panel
Method (2):
on the starter
Method (3):
with an external setting switch
Remote Operation
cd
(2)
(3)⑧⑨
②③
⑤
①
⑥
a
Power
Supply
16
CN16
51
CN17
41
CN8
21
CN2
19
CN1
17
CN15
17
Y3 Y1Y1
CPU
Y52C
Y2D
Y52
CN13
13
CN3
15
CN5
17
CN4
17
CN6
15
CN14
41
Y42
Y6
C38
C4D
C39
ICO
GND
CN11 CN12
14
CN18
13
CN19
13
CN22
14
CN21
15 12
CN10
1
18
2
CN9
SW1
14
SW2
CN7
HC30CPU−
SW1
ON
OFF
ON
OFF
DIPSwitch
PrintedCircuitBoard
(2)④
(3)④
Settingof
RemoteOperation
1234
4
5〜8
CAUTION
SettingofRemote
Operationwiththe
ExternalSettingSwitch
Except when you proceed to
an override operation, do not
change the standard factory
settings for the No. 5 to 8 pins.
Otherwise, a proper control al-
gorithm is lost.