EasyManua.ls Logo

Hitachi HTS542516K9SA00 - Check Power Mode (E5 H;98 H); Table 43 Check Power Mode Command (E5 H;98 H)

Hitachi HTS542516K9SA00
171 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
5K250 (SATA) OEM Specification
Page 76 of 171
14.1 Check Power Mode (E5h/98h)
Command Block Output Registers Command Block Input Registers
Register 7 6 5 4 3 2 1 0 Register 7 6 5 4 3 2 1 0
Data - - - - - - - - Data - - - - - - - -
Feature - - - - - - - - Error ...See Below...
Sector Count - - - - - - - - Sector Count V V V V V V V V
LBA Low - - - - - - - - LBA Low - - - - - - - -
LBA Mid - - - - - - - - LBA Mid - - - - - - - -
LBA High - - - - - - - - LBA High - - - - - - -
Device - - - - - - - - Device - - - - - - - -
Command 1 1 1 0 0 1 0 1 Status ...See Below...
Error Register Status Register
7 6 5 4 3 2 1 0 7 6 5 4 3 2 1 0
CRC UNC 0 IDN 0 ABT T0N AM
N
BSY RDY DF DSC DRQ COR IDX ERR
0 0 0 0 0 V 0 0 0 0 0 - - 0 0 V
Table 43 Check Power Mode Command (E5h/98h)
The Check Power Mode command will report whether the device is spun up and the media is
available for immediate access.
Input Parameters From The Device
Sector Count
The power mode code. The command returns FFh in the Sector Count Register if the spindle
motor is at speed and the device is not in Standby or Sleep mode. Otherwise, the Sector Count
Register will be set to 0.

Table of Contents