raidcom delete path
Error message
Executing/
Async
Error code
Description
SSB1 SSB2
Get Command
Status
Async 2E11 8011 The operation cannot continue because the
microcode is being replaced.
CMDRJE Executing 2E11 9400 The command cannot be accepted. After a while,
execute the same command.
CMDRJE Executing 2E20 4100 There is no external volume group.
CMDRJE Executing 2E20 4300 There is no external connection path.
CMDRJE Executing 2E20 4400 WWN is not registered.
CMDRJE
Get Command
Status
Executing/
Async
2E20 4500 There is no path group.
CMDRJE Executing 2E20 8401 The specified virtual port is not defined.
CMDRJE
Get Command
Status
Executing/
Async
2E23 4300 Paths cannot be deleted because there are no
normal paths.
CMDRJE Executing 2E30 8400 The port attribute is not External (ELUN).
CMDRJE Executing 2E30 840E The command cannot be executed with the
specified port attribute.
CMDRJE Executing 2EDA 00EE The command cannot be accepted. After a while,
execute the same command.
Get Command
Status
Async 2EDA FEEC An internal error occurred.
Call Hitachi Data Systems customer support.
Get Command
Status
Async 2EDA FFFF An internal error occurred.
Call Hitachi Data Systems customer support.
CMDRJE Executing B980 B901 The command was rejected because the specified
port is for NAS platform (System LU).
CMDRJE Executing B980 B902 The command was rejected because the specified
port is for NAS platform (User LU).
Table 9-102 SSB codes returned by raidcom add path
raidcom add path
Error message
Executing/
Async
Error code
Description
SSB1 SSB2
CMDRJE Executing 2E00 4500 The path group is not in the enabled range.
CMDRJE Executing 2E00 8400 The value of the specified port is incorrect.
CMDRJE Executing 2E02 8403 The specified virtual port number is out of range.
9-152
Troubleshooting
Command Control Interface User and Reference Guide