Chapter 4 List of Data Settings
4 - 10
Code Function name Monitored data or setting
Default
Setting
during
operation
(allowed
or not)
Change
during
operation
(allowed
or not)
_FF
Intelligent input terminals
C001 Terminal [1] function (*2)
01 (RV: Reverse RUN), 02 (CF1: Multispeed 1 setting),
03 (CF2: Multispeed 2 setting),
04 (CF3: Multispeed 3 setting),
05 (CF4: Multispeed 4 setting), 06 (JG: Jogging),
07 (DB: external DC braking),
08 (SET: Set 2nd motor data),
09 (2CH: 2-stage acceleration/deceleration),
11 (FRS: free-run stop), 12 (EXT: external trip),
13 (USP: unattended start protection),
14: (CS: commercial power source enable),
15 (SFT: software lock),
16 (AT: analog input voltage/current select),
17 (SET3: 3rd motor control), 18 (RS: reset),
20 (STA: starting by 3-wire input),
21 (STP: stopping by 3-wire input),
22 (F/R: forward/reverse switching by 3-wire input),
23 (PID: PID disable), 24 (PIDC: PID reset),
26 (CAS: control gain setting),
27 (UP: remote control UP function),
28 (DWN: remote control DOWN function),
29 (DWN: remote control data clearing),
31 (OPE: forcible operation), 32 (SF1: multispeed bit 1),
33 (SF2: multispeed bit 2), 34 (SF3: multispeed bit 3),
35 (SF4: multispeed bit 4), 36 (SF5: multispeed bit 5),
37 (SF6: multispeed bit 6), 38 (SF7: multispeed bit 7),
39 (OLR: overload restriction selection),
40 (TL: torque limit enable),
41 (TRQ1: torque limit selection bit 1),
42 (TRQ2: torque limit selection bit 2),
43 (PPI: P/PI mode selection),
46 (LAC: LAD cancellation),
50 (ADD: trigger for frequency addition [A145]),
51 (F-TM: forcible-terminal operation),
53 (KHC: cumulative power clearance),
56 (MI1: general-purpose input 1),
57 (MI2: general-purpose input 2),
58 (MI3: general-purpose input 3),
59 (MI4: general-purpose input 4),
60 (MI5: general-purpose input 5),
61 (MI6: general-purpose input 6),
62 (MI7: general-purpose input 7),
63 (MI8: general-purpose input 8),
64(EMR: Emergency stop signal),
65 (AHD: analog command holding),
74 (PCNT: pulse counter), 75 (PCC: pulse counter clear),
no
(
NO: no assi
g
nment
)
18
(*2)
¯ {
C002 Terminal [2] function 16 ¯ {
C003 Terminal [3] function (*2)
03
(*2)
¯ {
C004 Terminal [4] function 02 ¯ {
C005 Terminal [5] function 01 ¯ {
C006 Terminal [6] function 06 ¯ {
C007 Terminal [7] function 11 ¯ {
C008 Terminal [8] function 13 ¯ {
C011 Terminal [1] active state 00 (NO) / 01 (NC) 00 ¯ {
C012 Terminal [2] active state 00 (NO) / 01 (NC) 00 ¯ {
C013 Terminal [3] active state 00 (NO) / 01 (NC) 00 ¯ {
C014 Terminal [4] active state 00 (NO) / 01 (NC) 00 ¯ {
C015 Terminal [5] active state 00 (NO) / 01 (NC) 00 ¯ {
C016 Terminal [6] active state 00 (NO) / 01 (NC) 00 ¯ {
C017 Terminal [7] active state 00 (NO) / 01 (NC) 00 ¯ {
C018 Terminal [8] active state 00 (NO) / 01 (NC) 00 ¯ {
C019 Terminal [FW] active state 00 (NO) / 01 (NC) 00 ¯ {
*2 When the emergency stop function is enabled (SW1 = ON), "18" (RS) and "64" (EMR) are forcibly written to parameters "C001" and "C003",
respectively. (You cannot arbitrarily write "64" to "C001".) If the SW1 signal is turned off and then turned on, "no" (no assignment) is set in parameter
"C003".