LEDs Meaning
Medium ash
(once every .8
seconds)
The server needs attention, and a non-critical failure has been
detected, for e
xample, a fan or po
wer supply has failed. Flashes once
every .8 seconds.
O Normal operation.
10 Gigabit Ethernet cluster interconnect ports
The 10 gigabit per second Ethernet (10 GbE) cluster ports allow you to connect cluster
nodes together. The cluster ports are used only in a cluster conguration. The 10 GbE
ports oper
ate at speeds of ten (10) gigabits per second.
The HNAS 4060, 4080, and 4100
models use an enhanced small form factor pluggable (SFP+) optical connector.
Do not use the 10 GbE cluster interconnect ports to connect to the customer data
network (also known as the public data network).
For HNAS 4060, 4080, and 4100 models, the 10 GbE SFP+ transceiver modules are
removable and interchangeable.
Note: When r
emo
ved, the 10 GbE and 8 GB Fibre Channel (FC) SFP+ storage
modules are indistinguishable from one another except for their part
numbers. The part number is located on the side of the module housing and
is only visible when the module is removed. Part number prexes are
dierent as follows:
■
10 GbE: FTLX<number>
■
FC: FTLF<number>
Figure 20 10 GbE cluster interconnect ports label
10 Gigabit Ethernet cluster interconnect ports
Chapter 4: Hitachi NAS Platform server components
Hitachi NAS Platform and Hitachi Unied Storage Series 4000 Hardware Reference 52