EasyManua.ls Logo

Hitachi RAC-07CH5 - Page 54

Hitachi RAC-07CH5
68 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
58
1) When the Automatic
operation mode is
selected, Automatic
does not change by
pressing the fan speed
select button.
2) The room temperature
setting is not displayed.
3) Pressing the room
temperature control button
develops transmit mark
and sounds a
receive sound but does
not display the room
temperature setting.
Q20
Wireless remote controller
The room temperature
sensing thermistor in the
indoor unit detects the room
temperature and, according
to the particular temperature,
automatically performs
Cooling or Dehumidifying
operation.
The value indicated not at an
Automatic but manual
operation is not the actual
room temperature but the
room temperature setting.
When the room temperature
setting is 16, pressing the
room temperature control
button V causes no
transmission. At 32,
pressing causes no
transmission either.
Q21
The room temperature is
settable within the range of
16 - 32 and not beyond.
A21
The timer cannot be set.
Q22
Is the current time set?
The timer cannot be set
unless the clock is adjusted
correctly.
A22
V
The current time disap-
pears soon.
Q23
The current time disappears
soon and the timer settting
indication takes a
precedence.
A23
When setting the current time,
its indication blinks for
approximately 3 minutes.
1) When the operation mode
is Automatic, the fan
speed is automatically
fixed to Automatic.
2) At an Automatic
operation, the room
temperature setting is not
displayed.
The room temperature is
automatically set as
follows.
At cooling
Set at 27°C.
At dehumidifying
Set to a temperature
slightly lower than the
room temperature.
At heating
Set at 23°C.
3) At an Automatic
operation, the room
temperature setting is not
displayed.
However, every pressing
or V button
changes 1°C within the
range of:
27±3°C when cooling,
23±3°C when heating.
A20