EasyManua.ls Logo

Hitachi RAC-07CH5 - INSTALLATION GUIDE; Unit Installation (Models 07;09)

Hitachi RAC-07CH5
68 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
6
MODEL RAS-07CH5 / RAC-07CH5 and RAS-09CH5 / RAC-09CH5
Figure showing the installation of Indoor anf Outdoor unit
The installation height of indoor unit must be 2.3m or more in a non public area
CAUTION
!
above 50mm
above 100mm
above
0.45m
above 300mm
must not bend
above 100mm
2,300mm or more
1
2
Maximum pipe length 10m
Minimum pipe length 5m
Plug
above 100mm
above 300mm
above 200mm
above 100mm
give clearance
as wide as possible
above 50mm when
installed on the
ceiling of balcony
above 200mm
The difference in height
between the indoor and
outdoor unit should be kept
max 5m.
The connecting pipe, no
matter big or small, should
all be insulated with
insulation pipe and then
wrapped with vinyl tape.
(The insulator will
deteriorate if it is not
wrapped with tape).
The connection of insulated
drain hose.
Please use insulated drain
hose for the indoor piping
(commercial product).
The indoor piping should be
insulated with the enclosed
insulation pipe. (If the insulator
is insufficient, please use
commersial products).
inner diameter ø 16mm
5a

Related product manuals