EasyManua.ls Logo

Hitachi RAC-25WPB - Auto Swing Operation; Powerful Operation

Hitachi RAC-25WPB
148 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
– 11 –
ENGLISH
AUTO SWING OPERATION
Ƶ To start Vertical Auto Swing
Ƶ To cancel Vertical Auto Swing
NOTE
ƽ
During cooling and dehumidifying operation, do not keep
the deflectors swinging or in the lower position (in the case
of vertical auto swing) for a long time. It may cause dew
condensation on the deflectors.
Press (AUTO SWING (VERTICAL)) button. The
deflector(s) will start to swing up and down.
󰷅󰷅is displayed on the LCD.
Press (AUTO SWING (VERTICAL)) button again. The
deflector(s) will stop in the current position.
󰷅󰷅 disappeared from the LCD.
ƽ
ƽ
CAUTION
s When operating the unit in cooling operation with the air deflector facing down and moving automatically
for a long period of time, water will be condensed on the air deflector and drips down occasionally. This
will wet your furniture.
Vertical
When
heating,
about 50°
When cooling,
dehumidifying
about 40°
about
30°
about 10°
about 40°
When cooling,
dehumidifying
When heating
about 10°
about 45°
Horizontal
Horizontal
– 12 –
POWERFUL OPERATION
ƽ By pressing (POWERFUL) button during AUTO, HEATING, DEHUMIDIFYING, COOLING or FAN
operation, the air conditioner performs an the maximum power.
During POWERFUL operation, cooler or warmer air will be blown out from indoor unit for COOLING of
HEATING operation respectively.
Ƶ To start POWERFUL operation
Ƶ To cancel POWERFUL operation
1
NOTE
ƽ When SLEEP mode, ECO mode, SILENT mode or LEAVE HOME mode is selected, POWERFUL
operation is cancelled.
ƽ During POWERFUL operation, capacity of the air conditioner will not increase
if the air conditioner is already running at maximum capacity.
just before defrost operation (when the air conditioner is running in HEATING operation).
ƽ After auto restart, POWERFUL operation is cancelled and previous operation shall start.
For multi model connections, POWERFUL operation may not function depending on operation conditions.
Press (POWERFUL) button during operation.
ƽ
” is displayed on the LCD.
POWERFUL operation ends in 20 minutes. Then the system
automatically operates with the previous settings used before
POWERFUL operation.
Press
(POWERFUL) button again.
POWERFUL operation stops.
” disappears from the LCD.
ƽ
Press (START/ STOP) button.Or
ƽ
ƽ
15

Table of Contents

Other manuals for Hitachi RAC-25WPB

Related product manuals