RAM-130QH5 continued
Cooling
Combination
of Indoor Unit
TotalCapacity Rating Total Power Ampere(A)
EER
Capacity Rating
Total
Power Ampere(A)
EER
(kW)
(kW) (kW) (Range) (kW) Consumption(W) at 230V (kW) (Range) Consumption(W) at 230V
Outdoor UnitOutdoor Unit
Multizone Combinations
Heating
(1.8+3.5+3.5)+ (1.30+2.50+2.50)+ 4190 (1.40+2.90+2.90)+ 3800
(2.5+2.5+3.5) 15.3 (1.85+1.85+2.60) 12.60
(200-4400) 18.4 3.01 B (2.23+2.23+2.74) 14.40 (200-4220) 16.7 3.79 A
(1.50-13.20) (1.50-14.40)
(2.5+2.5+2.5)+ (2.10+2.10+2.10)+ 4190 (2.40+2.40+2.40)+ 3800
(2.5+2.5+2.5) 15.0 (2.10+2.10+2.10) 12.60
(200-4400) 18.4 3.01 B (2.40+2.40+2.40) 14.40 (200-4220) 16.7 3.79 A
(1.50-13.20) (1.50-14.40)
(2.5+2.5+2.5)+ (2.10+2.10+2.10)+ 4190 (2.40+2.40+2.40)+ 3800
(2.5+2.5+3.5) 16.0 (1.85+1.85+2.60) 12.60
(200-4400) 18.4 3.01 B (2.23+2.23+2.74) 14.40 (200-4220) 16.7 3.79 A
(1.50-13.20) (1.50-14.40)
(2.5+2.5+3.5)+ (1.85+1.85+2.60)+ 4190 (2.23+2.23+2.74)+ 3800
(2.5+2.5+3.5) 17.0 (1.85+1.85+2.60) 12.60
(200-4400) 18.4 3.01 B (2.23+2.23+2.74) 14.40 (200-4220) 16.7 3.79 A
(1.50-13.20) (1.50-14.40)
Six Units
* At least four indoor units should be connected.
* One unit indicated are only for one unit operation when four indoor units or more are connected.
* Two units indicated are only for two units operation when four indoor units or more are connected.
* Three units indicated are only for three units operation when four indoor units or more are connected.
* Four units indicated are only for four units operation when four indoor units or more are connected.
* Five units indicated are only for five units operation when four indoor units or more are connected.
Outdoor Connection Terminal 4 Unit Connection 5 Unit Connection 6 Unit Connection
Indoor 1 1.8kW, 2.5kW
Indoor 2 1.8kW, 2.5kW, 3.5kW 1.8kW, 2.5kW, 3.5kW 1.8kW, 2.5kW, 3.5kW*
Indoor 3 1.8kW, 2.5kW, 3.5kW, 5.0kW 1.8kW, 2.5kW, 3.5kW, 5.0kW 1.8kW, 2.5kW, 3.5kW
Indoor 4 1.8kW, 2.5kW 1.8kW, 2.5kW
Indoor 5 1.8kW, 2.5kW, 3.5kW 1.8kW, 2.5kW, 3.5kW* 1.8kW, 2.5kW, 3.5kW*
Indoor 6 1.8kW, 2.5kW, 3.5kW, 5.0kW 1.8kW, 2.5kW, 3.5kW 1.8kW, 2.5kW, 3.5kW
3.5kW*, for Indoor 1 and Indoor 4 with 1.8kW indoor connection only.

Other manuals for Hitachi RAC-50NH5