CONTROL AND FUNCTION
26
9
1. In case failure occurs to the air conditioner, by pressing (INFO) button, an error code will be displayed.
2. Direct the remote controller towards the receiver of indoor unit (within 2 meters in from of indoor unit) and press
(INFO) button.
3. Wait for 2 seconds for signal transmission and the error code will be displayed.
TIMER LAMP BLINKING LED301
INDOOR
- -
000
00
Normal
1 time
001
00
Refrigerant cycle fault
2 times - - Outdoor unit is under forced operation
3 times 9 times
003
00
Communication error between indoor and outdoor
units
9 times -
009
00
Indoor thermistor
10 times -
010
00
Abnormal rotating numbers
13 times -
013
00
IC401 data reading error
OUTDOOR
4 times 2 times
002
01
Peak current cut
4 times 3 times
003
01
Compressor abnormal low speed rotation
4 times 4 times
004
01
Compressor switching failure
4 times 5 times
005
01
Overload lower limit cut
4 times 6 times
006
01
OH thermistor temperature rise
4 times 7 times
007
01
Abnormal outdoor thermistor
4 times 8 times
008
01
Acceleration defective
4 times 9 times
009
01
Communication error
4 times 10 times
010
01
Abnormal power source
4 times 11 times
011
01
Fan stop for strong wind
4 times 12 times
012
01
Fan motor fault
4 times 13 times
013
01
EEPROM reading error
4 times 14 times
014
01
Active converter defective
4 times 15 times
015
01
Abnormal PWB circuit