The intermittent fan control during thermo off in Heating mode can be changed by the remote controller.
(This procedure should be done only by service personnel.)
It is possible to select from 3 patterns.
PROCEDURE
1. Press
  
[START/STOP] button,
  
[Mon-Sun] button and press
  
[RESET] button
simultaneously.
Release
  
[RESET] button only and make sure that all marks on the remote controller display
are indicated, then release
  
[START/STOP] button and
  
[Mon-Sun] button.
Remote controller now enters "Intermittent Fan Control Change Mode".
Default : Pattern 1
HOW TO CHANGE THE INTERMITTENT FAN CONTROL SETTING
2. Press [ROOM TEMPERATURE setting] [
(UP)]/[
(DOWN)] buttons.
(The intermittent pattern changed with indoor unit beep sound.)
Transmission sign lights up with beep from indoor unit simultaneously.
Pattern 1 Pattern 2 Pattern 3
NOTE :
(1) The indication of the selected intermittent pattern will disappear after 10 seconds.
(2) The selected intermittent pattern will remain unchanged after the unit is turned off.
70