Hitachi RAC-70WPA - Attaching the Air Purifying Filters

Hitachi RAC-70WPA
14 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
9
ENGLISH
CAUTION
CAUTION
NOTE
Claws
(4 places)
!
!
1
2
3
4
ATTACHING THE AIR PURIFYING FILTERS
Open the front panel
Pull up the front panel by holding it at both sides with
both hands.
Remove the Pre-Þ lter
Push upward to release the claws and pull out the
Pre-Þ lter.
Attaching the air purifying Þ lters
Attach the air purifying Þ lters to the frame by gently
compress its both sides and release after insertion
into Pre-Þ lter frame.
Attach the Pre-Þ lters
Attach the Pre-Þ lters by ensuring that the surface writ-
ten “FRONT” is facing front.
After attaching the Pre-Þ lters, push the front panel at
three arrow portions as shown in Þ gure and close it.
Cleaning and maintenance must be carried out when Þ lter lamp lights. Before cleaning, stop operation
and switch off the power supply.
Do not bend the air purifying Þ lter as it
may cause damage to the structure.
Please do not smell direct from source
of Þ lter.
In case of removing the air purifying Þ lters, please follow the above procedures.
The cooling capacity is slightly weakened and the cooling speed becomes slower when the air purifying
Þ lters are used. So, set the fan speed to "HIGH" when using it in this condition.
Do not operate the air conditioner without Pre-Þ lter. Dust may enter the air conditioner and fault may
occur.