7. Initial Setting Circuit (IC401)
When power is supplied, the microcomputer reads the data in IC401 (E
2
PROM) and sets the preheating
activation value and the rating and maximum speed of the compressor, etc. to their initial values.
Data of self-diagnosis mode is stored in IC401; data will not be erased even when power is turned off.
Fig. 7-1
Microcomputer
External ROM
SCL
SDA
0V
0V
0V
5V
5V 5V
C401
IC401 (E
2
PROM)
R404
R403
27
26
1
2
3
4
8
7
6
5
}