NO. 0629E
SPECIFICATIONS AND PARTS ARE SUBJECT TO CHANGE FOR IMPROVEMENT
ROOM AIR CONDITIONER
INDOOR UNIT + OUTDOOR UNIT
SEPTEMBER 2017
Refrigeration & Air-Conditioning Division
SERVICE MANUAL
REFER TO THE FOUNDATION MANUAL
TECHNICAL INFORMATION
FOR SERVICE PERSONNEL ONLY
RAD-50PPD
RAD-60PPD
CONTENTS
SPECIFICATIONS ------------------------------------------------------ 5
HOW TO USE ---------------------------------------------------------- 8
CONSTRUCTION AND DIMENSIONAL DIAGRAM ---------52
MAIN PARTS COMPONENT --------------------------------------55
WIRING DIAGRAM ---------------------------------------------------57
CIRCUIT DIAGRAM --------------------------------------------------62
BLOCK DIAGRAM ----------------------------------------------------71
BASIC MODE ----------------------------------------------------------73
REFRIGERATING CYCLE DIAGRAM---------------------------83
DESCRIPTION OF MAIN CIRCUIT OPERATION -----------84
SERVICE CALL Q & A --------------------------------------------103
TROUBLE SHOOTING --------------------------------------------106
PARTS LIST AND DIAGRAM ------------------------------------ 141
RAD-50PPD/RAC-50NPD
RAD-60PPD/RAC-60NPD
After installation
WIRELESS REMOTE
CONTROLLER
(SPX-RCKA1)
WIRED REMOTE
CONTROLLER
(SPX-RCDA)
WIRED REMOTE
CONTROLLER
(SPX-WKT3)
For SPX-WKT3, Please refer to it’s
own manual.
OPTIONAL
RAC-50NPD
RAC-60NPD
(W)
(A)
(kW)
(B.T.U./h)
(W)
(A)
(kW)
(B.T.U./h)
W
H
D
(kg)
(DUCT TYPE)
TYPE
MODEL
POWER SOURCE
TOTAL INPUT
TOTAL AMPERES
CAPACITY
TOTAL INPUT
TOTAL AMPERES
CAPACITY
DIMENSIONS
(mm)
NET WEIGHT
SPECIFICATIONS
COOLING
INDOOR UNIT
RAD-50PPD
900
270
720
35
OUTDOOR UNIT
RAC-50NPD
INDOOR UNIT
RAD-60PPD
OUTDOOR UNIT
RAC-60NPD
850
750
298
50
850
750
298
50
900
270
720
35
1,420 (300 ~ 2,500)
6.52 – 5.98
5.00 (1.20 ~ 5.80)
17,060 (4,090 ~ 19,780)
1 Ø, 50/60 Hz, 220-240V 1 Ø, 50/60 Hz, 220-240V
1,710 (300 ~ 2,600)
7.85 – 7.20
6.00 (1.20 ~ 6.50)
20,470 (4,090 ~ 22,170)
HEATING
1,570 (300 ~ 2,650)
7.21 – 6.61
6.00 (1.20 ~ 6.80)
20,470 (4,090 ~ 23,200)
1,840 (300 ~ 2,650)
8.45 – 7.74
7.00 (1.20 ~ 8.00)
23,880 (4,090 ~ 27,290)
Question and Answer IconNeed help?

Do you have a question about the Hitachi RAD-50PPD and is the answer not in the manual?

Overview

This document is a service manual for Hitachi room air conditioners, specifically models RAD-50PPD/RAC-50NPD and RAD-60PPD/RAC-60NPD. It provides technical information for service personnel, covering specifications, usage, construction, main components, wiring diagrams, circuit diagrams, block diagrams, basic operation modes, refrigerating cycle diagrams, main circuit operation descriptions, service FAQs, troubleshooting, and parts lists.

Function Description

The Hitachi room air conditioner is designed to provide cooling, heating, and dehumidifying functions for indoor spaces. It consists of an indoor unit (RAD-50PPD/RAD-60PPD) and an outdoor unit (RAC-50NPD/RAC-60NPD). The system can be controlled via a wireless remote controller (SPX-RCKA1) or optional wired remote controllers (SPX-RCDA, SPX-WKT3).

The device offers various operation modes:

  • Automatic Operation: The unit automatically determines the heating or cooling mode based on the current room temperature. The mode can change if the room temperature varies, but not if the indoor unit is connected to a multi-type outdoor unit.
  • Heating Operation: Provides heating when the outdoor temperature is above -15°C and below 21°C. If the temperature is too warm (over 21°C), the heating function may not work to protect the device. Defrosting occurs periodically (5-10 minutes every hour) when frost forms on the outdoor unit's heat exchanger.
  • Dehumidifying Operation: Reduces room humidity. It operates when the room temperature is over 16°C; below 15°C, this function will not work. The recommended temperature range for dehumidifying is 20-26°C.
  • Cooling Operation: Provides cooling when the outdoor temperature is between -10°C and 43°C. High indoor humidity (80%) might cause dew formation on the air outlet grille.
  • Fan Operation: Allows the unit to function simply as an air circulator without heating or cooling.
  • POWERFUL Operation: Activates maximum power for faster heating, cooling, or dehumidifying. This mode automatically ends after 20 minutes. It is canceled if SLEEP, ECO, or SILENT modes are selected.
  • SILENT Operation: Reduces fan speed to ultra-low for quieter operation. This mode is canceled if POWERFUL operation is selected.
  • ECO Operation: An energy-saving function that automatically adjusts the set temperature and limits maximum power consumption. It cannot be used simultaneously with POWERFUL operation or during FAN operation.
  • LEAVE HOME (LH) and CLEAN (One Touch Clean) Operations: These are specific functions that can be activated via the wireless remote controller. The CLEAN operation dries the indoor heat exchanger to prevent mildew and takes 60 minutes, after which the unit switches off.
  • Timer Functions: Includes OFF Timer, ON Timer, ON/OFF Timer, ECO Sleep Timer, and Weekly Timer for scheduled operation.

Important Technical Specifications

The manual provides detailed specifications for both indoor and outdoor units:

  • Models:
    • Indoor Unit: RAD-50PPD, RAD-60PPD
    • Outdoor Unit: RAC-50NPD, RAC-60NPD
  • Power Source: 1 Ø, 50/60 Hz, 220-240V
  • Cooling:
    • Total Input: RAD-50PPD: 1,420 (300 ~ 2,500) W; RAD-60PPD: 1,710 (300 ~ 2,600) W
    • Total Amperes: RAD-50PPD: 6.52 – 5.98 A; RAD-60PPD: 7.85 – 7.20 A
    • Capacity: RAD-50PPD: 5.00 (1.20 ~ 5.80) kW / 17,060 (4,090 ~ 19,780) B.T.U./h; RAD-60PPD: 6.00 (1.20 ~ 6.50) kW / 20,470 (4,090 ~ 22,170) B.T.U./h
  • Heating:
    • Total Input: RAD-50PPD: 1,570 (300 ~ 2,650) W; RAD-60PPD: 1,840 (300 ~ 2,650) W
    • Total Amperes: RAD-50PPD: 7.21 – 6.61 A; RAD-60PPD: 8.45 – 7.74 A
    • Capacity: RAD-50PPD: 6.00 (1.20 ~ 6.80) kW / 20,470 (4,090 ~ 23,200) B.T.U./h; RAD-60PPD: 7.00 (1.20 ~ 8.00) kW / 23,880 (4,090 ~ 27,290) B.T.U./h
  • Dimensions (mm):
    • Indoor Unit (W x H x D): 900 x 270 x 720 mm
    • Outdoor Unit (W x H x D): 850 x 750 x 298 mm
  • Net Weight (kg):
    • Indoor Unit: 35 kg
    • Outdoor Unit: 50 kg
  • Refrigerant Charging Volume (Refrigerant R32): 1500g (for RAC-50NPD/RAC-60NPD). Pipes (MAX. 30M) (MIN. 3M) are chargeless.
  • Fan Motor: Indoor: 180W (RAD-50PPD/RAD-60PPD); Outdoor: DC47W (RAC-50NPD/RAC-60NPD).
  • Compressor: JX151XG1 (RAC-50NPD/RAC-60NPD).
  • Thermostat: IC type for both indoor and outdoor units.
  • Fuses: 3.15A for indoor unit (micro computer circuit); 3A for outdoor unit (micro computer circuit).

Usage Features

  • Remote Control: The wireless remote controller has a range of about 7 meters. It allows selection of operation mode (Auto, Heat, Dehumidify, Cool, Fan), fan speed (Auto, High, Med, Low, Silent), and room temperature. It also features buttons for POWERFUL, SILENT, INFO, ONE TOUCH CLEAN, LEAVE HOME, ECO, SLEEP TIMER, and various timer settings (ON/OFF, Weekly).
  • Calendar and Clock: The remote controller allows setting the calendar and clock, which is essential for timer functions.
  • Operation Mode Lock: The remote controller can fix the operation mode to Heating, Cooling, or Dehumidifying, preventing accidental changes.
  • Auto Restart Control: In case of power failure, the unit automatically restarts with previous settings once power is restored.
  • Effective Use: Recommendations include setting an average room temperature, closing curtains/blinds, ventilating regularly, cleaning the pre-filter every two weeks, and avoiding blocking air inlets/outlets.
  • User Information: Provides guidance on suitable room temperature, ventilation, timer usage, pre-filter cleaning, and avoiding interference from electrical products.

Maintenance Features

  • Safety Precautions: Emphasizes disconnecting power before disassembly, using genuine parts, proper wiring, and handling semiconductors carefully.
  • Regular Inspection: Recommends checking the earth line, mounting frame, power line plug, fuse, voltage, circuit breaker, air filter, outdoor unit airflow, and room temperature settings.
  • Pre-Filter Cleaning: Instructions for removing and cleaning the pre-filter using a vacuum cleaner or wet cloth.
  • Troubleshooting: Comprehensive guide for diagnosing and resolving issues, including self-diagnosis display codes, checking electrical parts (indoor and outdoor), refrigerant cycle, and communication faults.
  • Main Circuit Operation Description: Detailed explanation of power control, indoor fan motor drive circuit, remote control reception circuit, indoor/outdoor communication circuit, room temperature heat exchanger thermistor circuit, float switch, drain pump circuit, static pressure switch, wired remote control reception/transmission circuit, and dip switch settings.
  • Parts List and Diagram: Provides exploded views and lists of parts for both indoor and outdoor units, aiding in identification and replacement.

Hitachi RAD-50PPD Specifications

General IconGeneral
BrandHitachi
ModelRAD-50PPD
CategoryAir Conditioner
LanguageEnglish

Related product manuals