7
DUAL SYSTEM MULTI R.A.C.
RAM-55QH5
COOL / HEAT CAPACITY SPEC. FOR INDOOR UNITS
COMBINATIONS TO BE ABLE TO OPERATE SIMULTANEOUSLY
Whichever indoor units are installed, cooling and heating capacity depends on how many and which indoor units
are operating at that time.
POSSIBLE
COMBINATIONS
TO OPERATE
CAPACITY RATING
(kW)
(RANGE)
POWER
CONSUMPTION
(W)
AMPERE
(A)
220-240V
OUTDOOR UNIT
C O O L I N G
CAPACITY RATING
(kW)
(RANGE)
POWER
CONSUMPTION
(W)
AMPERE
(A)
220-240V
OUTDOOR UNIT
H E A T I N G
ONE UNIT
TWO UNIT
1.8
2.5
3.5
5.0
1.8+1.8
1.8+2.5
1.8+3.5
1.8+5.0
2.5+2.5
2.5+3.5
1.80
(1.00-2.50)
2.50
(1.00-2.80)
3.50
(1.00-3.90)
5.00
(1.00-5.60)
1.80+1.80
(1.50-4.00)
1.80+2.40
(1.50-4.60)
1.70+3.30
(1.50-5.60)
1.40+4.00
(1.50-5.90)
2.50+2.50
(1.50-5.60)
2.17+3.03
(1.50-5.70)
560
(200-750)
780
(200-980)
1160
(200-1280)
1780
(200-1960)
1190
(200-1300)
1310
(200-1450)
1650
(200-1820)
1795
(200-1980)
1650
(200-1820)
1730
(200-1900)
2.6-2.4
3.6-3.3
5.3-4.9
8.2-7.5
5.5-5.0
6.0-5.5
7.6-6.9
8.2-7.6
7.6-6.9
7.9-7.3
2.50
(1.10-3.20)
3.90
(1.10-4.70)
4.80
(1.10-5.80)
6.50
(1.10-7.20)
2.50+2.50
(1.50-5.20)
2.40+3.80
(1.50-6.30)
2.30+4.50
(1.50-7.20)
2.00+5.00
(1.50-7.20)
3.40+3.40
(1.50-7.20)
3.15+3.85
(1.50-7.20)
750
(200-1050)
1145
(200-1380)
1550
(200-1870)
2400
(200-2660)
1460
(200-1550)
1820
(200-1920)
1995
(200-2100)
2050
(200-2100)
2015
(200-2110)
2070
(200-2110)
3.4-3.2
5.3-4.8
7.1-6.5
11.0-10.1
6.7-6.1
8.4-7.7
9.2-8.4
9.4-8.6
9.3-8.5
9.5-8.7
ONE UNIT : The values indicated are only for one unit opration when two indoor units are connected.
3.5+3.5
2.70+2.70
(1.50-5.90)
1795
(200-1980)
8.2-7.6
3.60+3.60
(1.50-7.20)
2110
(200-2110)
9.7-8.9
2.5+5.0
1.80+3.60
(1.50-5.90)
1795
(200-1980)
8.2-7.6
2.70+4.50
(1.50-7.20)
2110
(200-2110)
9.7-8.9
RATING CONDITON (DRY BLUB / WET BULB)
COOLING
HEATING
INDOOR OUTDOOR
27 / 19 ˚C
20 / –˚C
35 / –˚C
7 / 6˚C