Ð 0203 Ð
Ð6Ð
AUTO
HEAT
DEHUMIDIFY
COOL
FAN
FAN SPEED
LOW
MED
HI
SLEEPING
STOP (CANCEL)
START (RESERVE)
START/STOP
TIME
TIMER SET
TIMER SELECTOR
ON TIMER
OFF TIMER
AUTO SWING
û
CH
RESET
û
CH
      
   
Point this window toward the indoor unit when controlling it.
The transmission sign blinks when a signal is sent.

This indicates the room temperature selected, current time, timer status, function
and intensity of circulation selected.
 !
Press this button to start operation. Press it again to stop operation.
 !
Use this button to set the sleep timer.
 !
Use these buttons to raise or lower the temperature setting. (Keep pressed, and
the value will change more quickly.)
 !
Use this button to set and check the time and date.
 !
 "
Use this button to select the operating mode. Every time you press it,
the mode will change from (AUTO) to (HEAT) to (DEHUMIDIFY) to
(COOL) and to (FAN) cyclically.
  "
This determines the fan speed. Every time you press this button, the intensity
of circulation will change from (AUTO) to (HI) to (MED) to (LOW)
(This button allows selecting the optimal or preferred fan speed for each operation
mode).
 #$ !
Controls the angle of the horizontal air deflector.
 "
Use this button to set the timer.
% !
Select the turn OFF time.
% !
Select the turn ON time.
& !
Time setting reservation.
 !
Cancel time reservation.
"! ' 
Do not put the remote controller in the following places.
Under direct sunlight.
In the vicinity of a heater.
Handle the remote controller carefully. Do not drop it on the floor,
and protect it from water.
Once the outdoor unit stops, it will not restart for about 3 minutes
(unless you turn the power switch off and on or unplug the power
cord and plug it in again).
This is to protect the device and does not indicate a failure.
If you press the FUNCTION selector button during operation, the
device may stop for about 3 minutes for protection.
 
Operate by pointing towards the signal receptor on the indoor unit. The range of control is
about 7 meters. Signal receivable angle range is approximately 70¡. However, if there is an
electronic light sensor device (inverter) in the room, signal may not be received or receivable
distance may become shorter.
Indoor unit must be install 1 meter or more away from lighting.
Handle the remote controller with care. Dropping it or getting it wet may compromise its
signal transmission capability.
After new batteries are inserted into the remote controller, the unit will initially require
approximately 10 seconds to respond to commands and operate.
Approximately 70
°
Ð7Ð
$(
 
The device will automatically determine the mode of operation, HEAT, COOL or DEHUMIDIFY depending on the current room
temperature. The selected mode of operation will change when the room temperature varies. However the mode of operation will
not change when indoor unit connected to multi type outdoor unit.
As the settings are stored in memory in the remote controller, you only have to press the
(START/STOP) button next time.
Press the FUNCTION selector so that the display indicates the (AUTO) mode of operation.
When AUTO has been selected, the device will automatically determine the mode of
operation, HEAT, COOL or DEHUMIDIFY depending on the current room temperature.
However the mode of operation will not change when indoor unit connected to multi type
outdoor unit.
If the mode automatically selected by the unit is not satisfactory, manually change the
mode setting (heat, dehumidify, cool or fan).
Press the (START/STOP) button.
Operation starts with a beep.
Press the button again to stop operation.
You can raise or lower the temperature setting as necessary by maximum of 3¡C.
Press the temperature button and the temperature setting will change by
1¡C each time.
The preset temperature and the actual room temperature may vary somewhat depending on
conditions.
The display does not indicate the preset temperature in the AUTO mode. If you change the
setting, the indoor unit will produce a beep.
)


°
RESET
Press the (FAN SPEED) button, AUTO and LOW is available.
& 
!  
If there is a power failure, operation will be automatically restarted when the power is resumed with previous operation mode
and airflow direction.
(As the operation is not stopped by remote controller.)
If you intend not to continue the operation when the power is resumed, switch off the power supply.
When you switch on the circuit breaker, the operation will be automatically restarted with previous operation mode and airflow
direction.
Note: 1. If you do not require Auto Restart Control, please consult your sales agent or OFF by remote control.
2. Auto Restart Control is not available when Timer or Sleep Timer mode is set.