C ontrol function
Operation mode
F an C ooling S ensor dehumidification Heating Automatic
At the time of heating
operation mode, the s ame
operation as for heating
is executed.
Defrosting of each operation
mode is executed.
7
P reheating
operation
8
Defrosting
(including automatic
fresh defrosting).
Notes :
E ven when the preheating signal is not given as input, heating operation is s tarted when
3 minutes have pass ed for T .
P reheating operation is executed at the time of operation s tart and after completion
of defrosting, and at all other times, there is no operation, independent of the preheating signal.
TA
(R evers e cycle defrosting)
10 min.
min.
TB
(S ilencing period)
30 s ec
TC
(C ycle balancing time)
30 s ec
TE
(Defros ting prohibition
time)
60 min.
min.
+0
-5
+0
-1
F or the time T E after start of heating operation, defros ting will not be
executed even when the defros ting s ignal is given as input.
When the res erve cycle defrosting TA has continued for the time
shown in the table on the left, the operation advances to T B and TC
independent of the defrosting s ignal.
When the power relay becomes O N after expiration of the time TE ,
defrosting will be started immediately with input of the defros ting s ignal.
Once defrosting has been completed, the defros ting signal is not
accepted for the time T E .
When a defrosting s ignal has been given as input at the time of s top
by means of the s tart/stop s witch or at the time of OF F timer count-up,
defrosting is executed before operation stop.
The defrosting s ignal is not accepted at the time of overload input.
S ensor dehumidification
C ooling strong
Automatic
Heating
F an
S ens or
dehumidification
C ooling
Heating
C ooling
Y es
Y es
Y es
Y es
Y es
Y es (automatic)
Y es
Y es
Y es
Y es
Y es
Y es
Y es
Y es
Y es
Y es
Y es
Y es
Y es
No
Y es
No
Heating wireless
Item
Operation s witching
Temporary switch
S ervice switch
Nice temperature reservation
Automatic fres h defrosting
Defrosting
P d cut 1
P d cut 2
P d cut 3
Heating load reduction
E xternal fan relay
R eversing valve relay
R eversing valve lock protection
S leep circuit
Heater operation at the time of sensor
dehumidification
Automatic blowing direction
F ilter sign
Wireless mode
Item
C ooling, S ensor 16 17.6
ON temperature dehumidification 24 25.6
Thermostat (Thermostat relay) 32 33.6
operation power relay Heating 16 16.7
(°C ) 24 24.7
32 32.7
Differential (°C )
0.33
−
−
Low-temperature (T1) ON (°C )
2.0
defrosting R es et (°C )
P reheating (T2) R eset (°C )
24.0
ON (°C )
18.0
−
−
P d cut 1 (T3) ON (°C )
45.0
(T4) R eset (°C )
42.0
P d cut 2 (T6) ON (°C )
57.0
(T7) R eset (°C )
53.0
(T5) F an R elay H Original (°C )
55.0
P d cut 3 (T8) ON (°C )
69.0
(T9) R eset (°C )
59.0
Table 1 S pecifications
Table 2 S ensor operation values
Other detailed specifications
1. When the room temperature ris es
within 3 minutes after thermostat
OF F during cooling operation with
automatic velocity, the blowing
velocity changes in the order of S
→ L → H in the same way as at
the time of thermos tat ON.
2. In case of T ele. control input during
stopped ON timer, operation will be
started at that time and the timer
will be cleared.
3. In case of T ele. control input during
operation of the OF F timer, the
operation will be stopped at that time
and the timer will be cleared.
4. E ven when operation s top is
executed at the time of outside fan
OF F by overload, automatic fresh
defrosting will not be executed.
5. In case of s witching to "Heating"
during "Automatic" heating
operation, the operation will be
continued as it is when the
thermostat is ON. 3 min delay will
not be entered. However, the s et
room temperature and the blowing
velocity will be according to the
remote control signal. T he same
applies for s witching from "Heating"
to "Automatic" heating.
6. In cas e of switching from "S ensor
dehumidification" operation to
"C ooling", as it is when the
thermostat is ON. 3 min delay will
not be entered. However, the s et
room temperature and the blowing
velocity will be according to the
remote control signal.
The same applies for s witching from
"C ooling" to "S ens or dehumidifica-
tion". T he same also applies for
"Automatic" s ensor dehumidification,
cooling "S ens or dehumidification",
"C ooling".
7. T he filter sign lights after operation
of the indoor fan for 100 hours . T he
time is cleared by the filter switch.
8. After entry into trouble mode (when
the indication lamp is flashing), the
rapid feed mode can not be
changed.
9. When operation by nice temperature
reservation is executed during sleep
operation, normal operation will be
continued, and the advance time
becomes the temperature difference
between the set temperature without
sleep shift and the room
temperature.
10. The 60 minutes of defrosting
prohibition are counted from
Thermostat ON after start/stop
switch ON. W hen the thermos tat is
OF F at the time of start/stop s witch
ON, the 60 minutes will be counted
from the time of thermos tat ON. The
initial OF F time is not counted.
C ounting starts when the thermos tat
becomes ON, and the count then
continues even if the thermos tat
becomes OF F .
11. In case of s witching from "Heating"
the reversing valve is held for 3
minutes .
12. The defrosting signal is not
accepted with overload input, and
the operation becomes as s hown
below when the overload input
disappears.
(1) When previously the
defrosting signal existed
without overload input,
defrosting will s tart
immediately.
(2) In cases other than the
above, defrosting will be
executed with a defrosting
signal in the condition without
overload input.
− 35 −
Indoor heat exchanger
thermistor temperature
T
1
F an relay H
P ower relay
S tick relay
Outside fan relay
Operation lamp
F an relay S
P ower relay
S tick relay
Outside fan relay
Operation lamp
Min. 3 minutes
TE
15 sec
15 minutes-T
E
30 sec
30 sec
C ompletion
Defros ting
start
30 sec
30 sec
2 s ec
10 sec
S tart/s top s witch
Defros ting signal
P reheating s ignal
F an relay H
F an relay L
F an relay S
P ower relay
S tick relay
Outside fan relay
R evers ing valve relay
Heater relay
Operation lamp
Hot keep lamp
2 s ec
10 sec
TA
30 sec 60 sec
3 minutes
TA
30 sec
60 sec
TB
TC
15 sec
S tart/s top s witch
Thermos tat signal
P reheating signal
F an relay H
F an relay L
F an relay S
P ower relay
Hot keep lamp
2 s ec
T
3 minutes
30 sec 30 sec
15sec
30 sec 30 sec
"S trong" circulation
2 s ec
Low P ower Dehumidification
(1) When the s et temperature is lower than the room temperature.
Dry Button
S et temperature
F an relay L
P ower relay
S tick relay
Opera tion lamp
L L L
+3
+2
+1
Ð1
Ð2
Ð3
1deg up
32
sec
0.2 sec
0.2 sec 0.2 sec
0.2
sec
0.2
sec
0.2
sec
32 s ec
60 minutes
6 min
1 min
6 min
1 min
● T he min. ON time of the power relay is 3 minutes , and the min. OF F time is also 3 minutes.
● T he indoor fan is not delayed in operation when the Dry button is pres sed ON.
Notes :
● F orced operation by Dry button ON is executed even with thermostat OF F .
● T he room temperature 30 sec after operation s tart minus 0.33 deg., becomes the s et temperature.
● W hen the room temperature is 16°C or lower, 16°C becomes the set temperature.
● T he other operation are the s ame as for (l).
● T he indoor fan is not delayed in operation when the Dry button is pressed ON.
L L L
Dry B utton
S et temperature
F an relay L
P ower relay
S tick relay
Operation lamp
1 deg up
-1
-2
-3
-4
0.66deg
0.33deg
32 s ec
60 minutes
32 s ec
0.2 sec 0. 2 sec 0.2
sec
0.2
sec
0.2 sec
(2) S et temperature higher than room temperature.
●
●
●
●
●
●
●
●
●
●
15.7
23.7
31.7
0.0
8.0
53.0
49.0
55.0
49.0
52.0
69.0
58.0
R AS -14B H1R AS -07B H1
R AS -09B H1
12.0