– 23 –
ENGLISH
Specifications of the One Hour More Timer
Even after the 1, 2 or 3 hrs. Sleep Timer has expired when cooling/dehumidifying, this function monitors the
room’s temperature and automatically operates and stops (1 hr. more timer operation) one more time according
to the condition of the room (monitoring time is a maximum of 4 hrs. after the timer expires).
The timer lamp of the indoor unit turns on while the room’s temperature is monitored after the 1, 2 or
3 hrs. timer expires and the
and on the remote controller turn on.
Cooling, Dehumidifying If the room temperature rises by 2°C, the device operates for 1 hr..
FRESH AIR IN DURING SLEEP MODE OPERATION
Press the button.
The device beeps when it has received the signal and the
on the remote
controller turns on.
If the Fresh Air In During Sleep Mode is configured and set while the air
conditioning is stopped, the Fresh Air In During Sleep Mode does not operate.
When Sleep is operated while cooling/dehumidifying, the air conditioning
automatically operates the “Fresh Air In During Sleep Mode”.
The “Two Way Air Exchange” lamp on the indoor unit indicators turns on during
Fresh Air In operating.
Even after the Sleep Timer of the air conditioning expires, the room temperature
and the outside temperature are monitored, while the One Hour More Timer
operates and monitors (page 23). If the outside temperature is cooler than
room temperature, the Fresh Air In operates.
To cancel, press the button again.
The
on the remote controller turns off.
CANCEL
1
By configuring the “Fresh Air In During Sleep Mode”, a fresh air in operation of blowing outside air into the room is
added during the “Sleep Timer” operation (page 22) while cooling/dehumidifying. (This cannot be configured when
heating operation.)
RAS-10_14JH3_Ope_EN 05/12/2008, 04:43 pm23
– 24 –
ADJUSTING THE AIR DEFLECTORS
Adjustment of the conditioned air in the upward and downward
directions.
The horizontal air deflector is automatically set to the proper angle
suitable for each operation. The deflector can be swing up and down
continuously and also set to the desired angle using the
(AUTO SWING)” button.
1
Vertical
about 15°
about 65°
When Cooling,
Dehumidifying
When heating
Vertical
about 40°
about 40°
Adjustment of the conditioned air to the left and right.
Hold the vertical air deflector as shown in the figure and adjust the conditioned air to the left and right.
2
Left side: Hold the third blade from the left
end of the air deflector to adjust the direction.
The pull for the blade is marked.
Right side: Hold the third blade from the right
end of the air deflector to adjust the direction.
The pull for the blade is marked.
If the “ (AUTO SWING)” button is pressed once, the
horizontal air deflector swings up and down. If the button is
pressed again, the deflector stops in its current position.
Several seconds (about 6 seconds) may be required before
the deflector starts to move.
Use the horizontal air deflector within the adjusting range
shown in the right.
When the operation is stopped, the horizontal air deflector
moves and stops at the position where the air closes.
CAUTION
In “Cooling” operation, do not keep the horizontal air deflector
swinging for a long time. Some dew may form on the
horizontal air deflector and dew may drop.
RAS-10_14JH4_Ope_EN 24