ON
OFF
OFF
OFF
300[1/min.]
ON
300[1/min.]
2' 33'' 2' 33''5''
Continued from No. 1
Manual cleaning
24
consecutive
hours later
Power
Operation stop key
Sleep key
Manual cleaning key
Product operation
Initialization
--> dust box
Dust box -->
initialization
Limit
switch
Initialization
side
Operation lamp
Vertical vane
Indoor unit fan
Open
Closed
The 30" after the cleaning has
590 [1/min.] as its upper limit.
Continued from No. 2
Cleaning unit
driving motor
ON
OFF
OFF
OFF
ON
300[1/min.]
2' 33'' 2' 33''5''
2' 33'' 2' 33''5''
Operation diagram 2 for filter cleaning
(manual and forcible cleaning)
Forcible cleaning
Manual cleaning possible more than
5 minutes after the last cleaning and
when the product is stopped.
Operation diagram for filter cleaning 3
(timer stopped)
More than 70 cumulative operating hours
Automatic cleaning when
the timer is stopped
Power
Operation stop key
Sleep key
Manual cleaning key
Product operation
Initialization
--> dust box
Dust box -->
initialization
Limit
switch
Initialization
side
Operation lamp
Indoor unit fan
Vertical vane
Open
Closed
(Lamps off)
(Lamps off)
Cleaning lamp
15 minutes