1. AIR FILTER
Clean the air lter, as it removes dust inside the room. In case the air lter is full of dust, the air ow
will decrease and the cooling capacity will be reduced. Further, noise may occur. Be sure to clean
the lter following the procedure below.
!
CAUTION
1
Open the front panel and remove the lter
Gently lift and remove the air cleansing and
deodorizing lter from the air lter frame.
2
Vacuum dust from the air lter and air cleansing
and deodorizing lter using vacuum cleaner. If
there is too much dust, rinse under running tap
water and gently brush it with soft bristle brush.
Allow lters to dry in shade.
3
Re-insert the air cleansing and deodorizing
lter to the lter frame. Set the lter with
“FRONT” mark facing front, and slot them
into the original state.
After attaching the lters, push the front panel
at three arrow portions as shown in gure and
close it.
!
CAUTION
Do not wash with hot water at more than 40°C. The lter may shrink.
When washing it, shake off moisture completely and dry it in the shade; do not expose it directly
to the sun. The lter may shrink.
Do not use detergent on the air cleansing and deodorizing lter as some detergent may deteriorate
the lter electrostatic performance.
NOTE:
Air cleansing and deodorizing lter should be cleaned every month or sooner if noticeable loading
occurs. When used overtime, it may loose its deodorizing function. For maximum performance, it
is recommended to replace it every 1 year depending on application requirements.