EasyManua.ls Logo

Hitachi RAS-18YH5 - Page 44

Hitachi RAS-18YH5
96 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Fig. 3-4
(1)Outdoor microcomputer (HIC) to indoor microcomputer
Serial Communications Format during Normal Communications
]
Example
]
When the outdoor message is all 0s
    
and indoor message is all 1s:
(3)Communications waveforms
Leader
100ms.
Leader
100ms.
When reset
(approx.100ms.)
When reset
(approx.10ms.)
35
(
V
)
34
(
V
)
36
(
V
)
0
7
0
7
7
7
0
33.3ms.
3
2
1
NO
0
Bit No.=0
7
0
7
0
7
0
7
Bit No.=0
3
2
1
(33.3ms.) (33.3ms.)
(33.3ms.)
Transmit/
receive
switching time
(4.95ms.)
(33.3ms.) (33.3ms.)
Outdoor message
Indoor message
(33.3ms.)(33.3ms.)
0
Character No.
1 frame
100ms.+33.3ms.
×
8+4.95ms.
371.35ms.
(2)Indoor microcomputer to outdoor microcomputer (HIC)
– 48 –