CAUTION
When the refrigerating cycle has been operated for a long time with the capillary tubes clogged or crushed
or with too little refrigerant, check the color of the refrigerating machine oil inside the compressor. If the
color has been changed conspicuously, replace the compressor.
MODEL RAM-50CNHZ2
COMPRESSOR MODEL GW20DN8A
PHASE SINGLE
RATED VOLTAGE AC 220 ~ 230 V
RATED FREQUENCY 50/60 Hz
POWER SOURCE FOR COMPRESSOR Vcc max = 360V
POLE NUMBER 4
COMPRESSOR MOTOR
Compressor Motor Specifications
CONNECTION
20°C
(68°F)
75°C
(167°F)
( )
RESISTANCE VALUE
2M = 1.05
2M = 1.28
(U)
(V)
(W)
WHITE
YELLOW
RED
WHITE
RED
YELLOW