Remote control judgment operation
Remote control judgment operation
OFF
ON
Dirt monitoring
Monitor lamp
Operation lamp
Indoor unit
Front panel
Vertical vane
Dirt judgment
Dirt judgment
value
Open
Closed
Mist and air
purification lamp
Product operation
status
Electrical dust
collector
Wind feed position
Stop
Dirt judgment canceled
Product operation
Dirt judgment canceled
(1) Setting "dirt monitoring" will cause the stainless plasma air purifier to run
automatically when it detects contaminated air.
(2) If dirt monitoring is activated while the product is stopped, wind feed will be
activated. At that time, the mist and air purification lamp will go on.
(3) If dirt monitoring is activated while the product is running, it will run in the
operation mode selected by remote control. At that time, the operation
lamp will be lit.
(4) For about 8 hours after a sleep operation is reserved, "dirt monitoring"
will be inhibited.
(5) A period of 14 days after "dirt monitoring" is set, the product will autom
atically cancel its settings.
Notes:
Mold monitoring
Monitor lamp
Operation lamp
Indoor unit
Vertical vane
Dehumidification
Humidity
3-minute
SS
Shut Shut
Dehumidification position
Lo in dehumidification
First time
20 minutes
3-minute
SS
20 minutes
3-minute
SS
20 minutes
3-minute
SS
Dehumidification position
Second time
Lo in dehumidification
Setting "mold monitoring" will activate the product as follows:
(1) The indoor unit will be operated for 3 minutes to detect the temperature and
humidity.
(2) When the temperature
10 and the humidity
70%, the product will
perform dehumidification (4 hours). If it deviates from the conditions,
it will stop for 20 minutes.
(3) After the product runs for 4 hours, it will stop for 20 minutes.
(4) The indoor unit is run for 3 minutes to detect the temperature and humidity.
(5) In second and subsequent mold monitoring operations, and if the temperature
10 and the humidity
70%, the product will begin dehumidification again.
If the product deviates from the conditions, it will stop for 20 minutes.
(6) When the humidity
60%, the product will stop.
(7) After the product stops for 20 minutes, it will go back to (4).
– 129 –