2ā€ˆā€ˆFeaturesā€ˆandā€ˆbenets
Generalā€ˆfeaturesā€ˆandā€ˆbenetsā€ˆofā€ˆtheā€ˆUTOPIAā€ˆPrimeā€ˆ/ā€ˆUTOPIAā€ˆIVXā€ˆPrimeā€ˆSeries
TCGB0136 rev.1 - 05/2021
23
2

Simultaneous operation on several indoor units for more homogeneous climatization in large
open spaces
Withā€ˆUTOPIAā€ˆPrimeā€ˆā€ˆisā€ˆpossibleā€ˆforā€ˆseveralā€ˆindoorā€ˆunitsā€ˆconnectedā€ˆtoā€ˆaā€ˆsameā€ˆoutdoorā€ˆunitā€ˆtoā€ˆoperateā€ˆwithā€ˆtheā€ˆsameā€ˆ
operation parameters and setting temperature, as it was a single indoor unit.
Allā€ˆindoorā€ˆunitsā€ˆareā€ˆatā€ˆtheā€ˆsameā€ˆThermo-ONā€ˆorā€ˆThermo-OFFā€ˆstatus.ā€ˆ
Simultaneousā€ˆoperationā€ˆimprovesā€ˆcomfortā€ˆversusā€ˆmonosplitā€ˆPACā€ˆapplicationsā€ˆbyā€ˆprovidingā€ˆaā€ˆbetterā€ˆairā€ˆhomogeneityā€ˆ
dueā€ˆtoā€ˆtheā€ˆbiggerā€ˆnumberā€ˆofā€ˆindoorā€ˆunitsā€ˆ(upā€ˆtoā€ˆ4),ā€ˆwhichā€ˆmeansā€ˆaā€ˆlessā€ˆcentralizedā€ˆairā€ˆī›€ow.ā€ˆComparedā€ˆversusā€ˆanotherā€ˆ
alternativesā€ˆasā€ˆmultisplitsā€ˆprovidesā€ˆlongerā€ˆpipingā€ˆdistancesā€ˆneededā€ˆforā€ˆtertiaryā€ˆapplications;ā€ˆcomparedā€ˆtoā€ˆminiā€ˆVRFā€ˆ
systemsā€ˆitā€ˆisā€ˆaā€ˆmoreā€ˆcostā€ˆefcientā€ˆsolution.ā€ˆ
Example for common room (Simultaneous operation).
Thermo-OFF
Thermo-OFF
Setting
Temperature

Reduction of local temperature irregularity and achievement of optimal room conditions
Withā€ˆUTOPIAā€ˆIVXā€ˆPrimeā€ˆrangeā€ˆitā€ˆisā€ˆpossibleā€ˆaā€ˆindividualā€ˆthermo-ON/OFFā€ˆcontrol,ā€ˆenablingā€ˆcontrolā€ˆofā€ˆmultipleā€ˆindoorā€ˆunitsā€ˆ
byā€ˆoneā€ˆremoteā€ˆcontrolā€ˆswitch.ā€ˆTheā€ˆairā€ˆconditioningā€ˆoperationā€ˆisā€ˆadjustedā€ˆtoā€ˆcontrolā€ˆtheā€ˆroomā€ˆtemperatureā€ˆasā€ˆappropriate,ā€ˆ
accordingā€ˆtoā€ˆtheā€ˆdifferentā€ˆair-conditioningā€ˆloadsā€ˆrequiredā€ˆforā€ˆtheā€ˆinteriorā€ˆzoneā€ˆandā€ˆtheā€ˆperimeterā€ˆzoneā€ˆofā€ˆeachā€ˆroom.ā€ˆAsā€ˆaā€ˆ
result,ā€ˆthisā€ˆfunctionā€ˆprovidesā€ˆcomfortableā€ˆairā€ˆconditioningā€ˆ(achievingā€ˆuniformā€ˆtemperatures)ā€ˆandā€ˆenergy-saving.
ā€¢ā€ˆ Interiorā€ˆZone:ā€ˆaā€ˆzoneā€ˆwhereā€ˆtemperatureā€ˆisā€ˆnotā€ˆaffectedā€ˆbyā€ˆdirectā€ˆsunlightā€ˆorā€ˆoutdoorā€ˆairā€ˆinow
ā€¢ā€ˆ Perimeterā€ˆZone:ā€ˆaā€ˆzoneā€ˆwhereā€ˆtemperatureā€ˆisā€ˆaffectedā€ˆbyā€ˆdirectā€ˆsunlightā€ˆorā€ˆoutdoorā€ˆairā€ˆinow
Example for one room (Individual operation with one remote control and operating cable for remote control):
Setting
Temperature
Termo-OFF Termo-ON

Easy rearrangement for individual rooms
Withā€ˆUTOPIAā€ˆIVXā€ˆPrimeā€ˆrangeā€ˆaā€ˆmultipleā€ˆindoorā€ˆunitsā€ˆcanā€ˆbeā€ˆinstalledā€ˆandā€ˆoperatedā€ˆindividuallyā€ˆevenā€ˆifā€ˆroomsā€ˆareā€ˆ
partitioned.ā€ˆIndividualā€ˆoperationā€ˆcanā€ˆbeā€ˆcontrolledā€ˆforā€ˆeachā€ˆroomā€ˆbyā€ˆconnectingā€ˆtheā€ˆremoteā€ˆcontrolā€ˆswitchā€ˆtoā€ˆeachā€ˆ
indoorā€ˆunit.ā€ˆItā€ˆisā€ˆpossibleā€ˆtoā€ˆoperateā€ˆtheā€ˆindoorā€ˆunitsā€ˆofā€ˆoccupiedā€ˆroomsā€ˆonly,ā€ˆresultingā€ˆinā€ˆenergyā€ˆsavingā€ˆandā€ˆī›€exibilityā€ˆforā€ˆ
rearrangement of partitions.
Example for multiple rooms (Individual operation).
Thermo-ON
Thermo-OFF
Thermo-OFF