1. Thermistor holder.
2. Holder.
3. Td Thermistor.
4. Thermistor fixing plate.
5. Rubber cap Th Thermistor.
6. Indication of terminal number.
7. Terminal box cover.
8. Compressor.
9. Compressor wires.
10. Fix it with screw.
11. Compressor wires (3 wires).
A. Details for compressor terminals.
8 Remove the suction pipe and discharge pipe from the compressor.
Be sure to separate the blazing burner flame sufficiently from the wires and electrical components around the brazed
part in order to avoid burning.