TC-12001
2-53
4-WAY CASSETTE
P5414946-rev.1
23
O
Wiring Connection (Twin, Triple and Quad Combinations for Simultaneous Operation)
< 3
I
220V/60Hz >
< 3
I
380-415V/50Hz >
< 3
I
380V/60Hz >
E
E
RS
12AB
Outdoor Unit Indoor Unit No.1
Main Switch
Main Switch
Remote
Control Switch
(Option)
Remote Control
Switch Cable
(Field Supplied)
Shielded Twist Pair Cable 0.75mm
2
This cable dose not need any polarity.
Do not apply an excessively high
voltage to this cable. (Rated Voltage: 5V)
Shielded Twist Pair Cable 0.75mm
2
This cable dose not need any polarity.
Do not apply an excessively high
voltage to this cable. (Rated Voltage: 5V)
Control Cable
Power Source Cable
Pay attention to the phase
of power source when wiring.
3~
220V / 60Hz
1~
220V / 60Hz
Earth
Wiring
12AB
Indoor Unit No.2
ELB
ELB
E12
E12AB
Indoor Unit No.3
E
12AB
Indoor Unit No.4
Pull Box Pull Box
Pull Box
RS RS RS
R
S
TMp
E
E
L2L3 N
L1
N
12AB
Outdoor Unit Indoor Unit No.1
Main Switch
Main Switch
Remote
Control Switch
(Option)
Remote Control
Switch Cable
(Field Supplied)
Shielded Twist Pair Cable 0.75mm
2
This cable dose not need any polarity.
Do not apply an excessively high
voltage to this cable. (Rated Voltage: 5V)
Shielded Twist Pair Cable 0.75mm
2
This cable dose not need any polarity.
Do not apply an excessively high
voltage to this cable. (Rated Voltage: 5V)
Control Cable
Power Source Cable
Pay attention to the phase
of power source when wiring.
L1
3N~
380V / 60Hz
1N~
220V / 60Hz
(3N~)
Earth
Wiring
L1
N
12AB
Indoor Unit No.2
ELB
ELB
E12
EL1
N
12AB
Indoor Unit No.3
EL1 N 1 2 A B
Indoor Unit No.4
Pull Box Pull BoxPull Box
E
E
L2L3 N
L1
N
12AB
Outdoor Unit Indoor Unit No.1
Main Switch
Main Switch
Remote
Control Switch
(Option)
Remote Control
Switch Cable
(Field Supplied)
Shielded Twist Pair Cable 0.75mm
2
This cable dose not need any polarity.
Do not apply an excessively high
voltage to this cable. (Rated Voltage: 5V)
Shielded Twist Pair Cable 0.75mm
2
This cable dose not need any polarity.
Do not apply an excessively high
voltage to this cable. (Rated Voltage: 5V)
Control Cable
Power Source Cable
Pay attention to the phase
of power source when wiring.
L1
3N~
380V-415V / 50Hz
1N~
220-240V / 50Hz
(3N~)
Earth
Wiring
L1
N
12AB
Indoor Unit No.2
ELB
ELB
E12
EL1
N
12AB
Indoor Unit No.3
EL1 N 1 2 A B
Indoor Unit No.4
Pull Box Pull BoxPull Box