Note:
Do not terminate the application for
cibly while it is running otherwise,
the message [32061-208063] might appear when you log on to the
maintenance utility.
If the message displays, use the following corrective action:
a. Open the Update Firmware window from the newly opened
Maintenance Utility window.
b. Verify the Update Firmware window is displaying. If the progress
window appears, the rmware is currently updating. Wait until the
rmware update is complete.
c. Perform the Force Release System Lock.
The following table shows the possible status conditions.
Status Description
Waiting Software waiting to be upgraded.
Softwar
e components are upgraded
individually.
In progress Software is running.
Completed Software upgrade is complete.
Failed Software upgrade failed. Click Update
to display the Update Firmware
window and review the error details.
Communication Timeout The completion of the rmware update
in time
1
is not conrmed.
Verify the state in the Update
Firmware window.
(Not Update) Not selected as a rmware upgrade
target.
Note:
1. When NAS Modules are not installed, the installation time is approximately 3.5
hours. When NAS modules are installed, the installation time is approximately 9
hours.
11. When the Update softwar
e and rmware window opens, click Conrm.
The Run Update Firmware window opens and the upgrade starts automatically.
12. When the following window opens, click Update.
Upgrading the storage management, SVP software, and storage system rmwar
e
Chapter 9: Upgrading the SVP software
Service Processor Technical Reference 186