EasyManua.ls Logo

Hitachi VSP 5000 Series - Page 78

Hitachi VSP 5000 Series
92 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Trap reference
code
Description Section Alert level
Host
report
1
SIM
22
SIM
23
SIM
13
d8 9x xx A Delta volume to be used by
the URMF/UR was redened
Failure
with paired
volumes
SERVICE Yes
5
d9 0x xx A change to an S-VOL was
received from the MCU (From
Simplex to Duplex Pending)
Failure
with paired
volumes
SERVICE Yes
5
d9 1x xx A change to an S-VOL was
received from the MCU (From
Simplex to Duplex)
Failure
with paired
volumes
SERVICE Yes
5
d9 2x xx A change to an S-VOL was
received from the MCU (From
Duplex Pending to Duplex)
Failure
with paired
volumes
SERVICE Yes
5
d9 3x xx A change to an S-VOL was
received from the MCU (From
Duplex Pending to Suspend)
Failure
with paired
volumes
SERVICE Yes
5
d9 4x xx A change to an S-VOL was
received from the MCU (From
Duplex to Suspend)
Failure
with paired
volumes
SERVICE Yes
5
d9 5x xx A change to an S-VOL was
received from the MCU (From
Duplex to Simplex)
Failure
with paired
volumes
SERVICE Yes
5
d9 6x xx A change to an S-VOL was
received from the MCU (From
Duplex Pending to Simplex)
Failure
with paired
volumes
SERVICE Yes
5
d9 7x xx A change to an S-VOL was
received from the MCU (From
Suspend to Simplex)
Failure
with paired
volumes
SERVICE Yes
5
d9 8x xx A change to an S-VOL was
received from the MCU (From
Suspend to Duplex Pending)
Failure
with paired
volumes
SERVICE Yes
5
d9 9x xx A change to an S-VOL was
received from the MCU (HOLD
-> PAIR)
Failure
with paired
volumes
SERVICE Yes
5
Failure trap reference codes