Trap reference
code
Description Section Alert level
Host
report
1
SIM
22
SIM
23
SIM
13
d9 ax xx A change to an S-VOL was
received from the MCU (HOLD
-> COPY)
Failure
with paired
volumes
SERVICE Yes
5
d9 bx xx A change to an S-VOL was
received from the MCU (HOLD
-> SMPL)
Failure
with paired
volumes
SERVICE Yes
5
d9 cx xx A change to an S-VOL was
received from the MCU (From
Simplex to Suspend)
Failure
with paired
volumes
SERVICE Yes
5
d9 dx xx A change to an S-VOL was
received from the MCU (SMPL
-> HOLD)
Failure
with paired
volumes
SERVICE Yes
5
d9 ex xx A change to an S-VOL was
received from the MCU
(PSUx(Suspend) -> HOLD)
Failure
with paired
volumes
SERVICE Yes
5
d9 fx xx A change to an S-VOL was
received from the MCU (From
Duplex to Duplex Pending)
Failure
with paired
volumes
SERVICE Yes
5
da 0x xx A change to an S-VOL was
received from the RCU (A
request for suspension was
received.)
Failure
with paired
volumes
SERVICE No
da 1x xx A change to an S-VOL was
received from the RCU (A
suspension transaction was
completed.)
Failure
with paired
volumes
SERVICE No
da 2x xx A change to an S-VOL was
received from the RCU (An
instruction to delete a pair was
received in the Suspend
status.)
Failure
with paired
volumes
SERVICE No
da 3x xx A change to an S-VOL was
received from the RCU (An
instruction to delete a pair was
received in the Duplex
Pending status.)
Failure
with paired
volumes
SERVICE No
Failure trap reference codes
Chapter 8: SIM codes
Hitachi Alert Notication Guide for VSP5000 Series 79