EasyManua.ls Logo

Hitachi VSP 5000 Series - Page 79

Hitachi VSP 5000 Series
92 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Trap reference
code
Description Section Alert level
Host
report
1
SIM
22
SIM
23
SIM
13
d9 ax xx A change to an S-VOL was
received from the MCU (HOLD
-> COPY)
Failure
with paired
volumes
SERVICE Yes
5
d9 bx xx A change to an S-VOL was
received from the MCU (HOLD
-> SMPL)
Failure
with paired
volumes
SERVICE Yes
5
d9 cx xx A change to an S-VOL was
received from the MCU (From
Simplex to Suspend)
Failure
with paired
volumes
SERVICE Yes
5
d9 dx xx A change to an S-VOL was
received from the MCU (SMPL
-> HOLD)
Failure
with paired
volumes
SERVICE Yes
5
d9 ex xx A change to an S-VOL was
received from the MCU
(PSUx(Suspend) -> HOLD)
Failure
with paired
volumes
SERVICE Yes
5
d9 fx xx A change to an S-VOL was
received from the MCU (From
Duplex to Duplex Pending)
Failure
with paired
volumes
SERVICE Yes
5
da 0x xx A change to an S-VOL was
received from the RCU (A
request for suspension was
received.)
Failure
with paired
volumes
SERVICE No
da 1x xx A change to an S-VOL was
received from the RCU (A
suspension transaction was
completed.)
Failure
with paired
volumes
SERVICE No
da 2x xx A change to an S-VOL was
received from the RCU (An
instruction to delete a pair was
received in the Suspend
status.)
Failure
with paired
volumes
SERVICE No
da 3x xx A change to an S-VOL was
received from the RCU (An
instruction to delete a pair was
received in the Duplex
Pending status.)
Failure
with paired
volumes
SERVICE No
Failure trap reference codes
Chapter 8: SIM codes
Hitachi Alert Notication Guide for VSP5000 Series 79

Table of Contents

Related product manuals