Mode Category Description Default MCU/RCU
449 Universal
Replicator
This SOM is used to enable and disable detection of
communication failur
es between the MCU and RCU.
Mode 449 = ON (default): On the MCU side,
checking read journal disruption from RCU is
disabled, and monitoring read journal failures is
disabled on the RCU side.
Mode 449 = OFF: Detecting communication failures
between the MCU and RCU is enabled.
Notes:
1. This SOM applies when disabling the detection
of communication failures between the MCU
and RCU in UR conguration is required.
2. When this SOM is set to ON, SOM 448 does not
work.
3. This SOM setting is not changed by microcode
upgrade.
4. This SOM is not eective for remote paths
between an Initiator port on the MCU and a
Target port on the RCU.
5. While a path from the RCU to MCU is
disconnected, if the UR pair remains in
Suspending or Deleting status, recover it in
accordance with the procedure in Recovery
from UR Failure in TROUBLE SHOOTING section
of Maintenance Manual.
ON MCU
System option modes
Appendix B: System option modes
System Administrator Guide for VSP Gx00 models and VSP Fx00 models 294

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Hitachi VSP Gx00 series and is the answer not in the manual?

Hitachi VSP Gx00 series Specifications

General IconGeneral
BrandHitachi
ModelVSP Gx00 series
CategoryStorage
LanguageEnglish

Related product manuals