Mode Category Description Default MCU/RCU
471 Thin Image Since the SIM-RCs generated when the Thin Image
pool usage r
ate exceeds the threshold value can be
resolved by users, these SIM-RCs are not reported to
the maintenance personnel. This SOM is used to
report these SIM-RCs to maintenance personnel.
The SIM-RCs reported by setting the SOM to ON are:
601xxx (Pool utilization threshold exceeded), 603000
(SM space warning).
Mode 471 = ON: These SIM-RCs are reported to
maintenance personnel.
Mode 471 = OFF: These SIM-RCs are not reported to
maintenance personnel.
Note: Set this SOM to ON when it is required to
inform maintenance personnel of these SIM-RCs.
OFF -