NOTE: Reset is not allowed in 10 second after trip.
NOTE: When error E08, E14 and E30 occur, reset operation by RS terminal or STOP/RESET key is
not accepted. In this case, reset by cycling power. If still same error occurs, perform initialization.
Restoring Factory Default Settings
You can restore all inverter parameters to the original factory (default) settings according to
area of use. After initializing the inverter, use the powerup test (please refer to Chapter 2 in
the Instruction Manual) to get the motor running again. If operation mode (std. or high
frequency) mode is changed, inverter must be initialized to activate new mode. To initialize
the inverter, follow the steps below.
(1) Select initialization mode in .
(2) If =, or , select initialization target data in .
(3) If =, or , select country code in .
(4) Set in .
(5) The following display appears for a few seconds, and initialization is completed with
displayed.
* Please change from" (Basic display)" to " (Full display)" in parameter
(Function code display restriction), in case some parameters cannot be displayed.