EasyManua.ls Logo

Hitachi WJ200 - HOIST OVER-WEIGHT FUNCTION

Hitachi WJ200
30 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Page 13
HOIST OVER-WEIGHT FUNCTION
The VFD is setup to use the output current to the motor as the over-weight function. The VFD uses (2) over-weight current
parameters. Over-weight (1) is when operating less than or equal to the low-speed frequency and over-weight (2) is when operating
above low-speed frequency. The VFD automatically switches between over-weight (1) and over-weight (2) based on the frequency.
Having (2) over-weights greatly increases over-weight accuracy and decreases the likelihood of a false over-weight condition.
The VFD has (3) configurations for the over-weight signal, external momentary, external maintained, Internal.
External momentary - will output a signal when the condition is met but will not maintain the output after the condition is no longer
met. This configuration also uses digital output 12 assigned to 52:Reverse DIR with a N.C contact status which is used to latch a relay.
External maintained - will output a signal when the condition is met and maintain the signal until the reset condition is met or power is
cycled.
Internal - does not require any external circuits to function. Internal works the same way as the external maintained but will internally
prevent the hoist up function until the reset condition is met or power is cycled.
HOW IT WORKS When the output current to the motor exceeds the value in the conditional over-weight current parameter for an
amount of time that exceeds the detection delay time, the conditional digital output will turn on and activate a 24v relay to interrupt
the hoist E-Stop circuit. The signal is turn off once the hoist has lowered for 2.0 seconds.
HOIST OVER-WEIGHT PARAMETERS
Function
Parameters
Example Value
Over-Weight Signal Output Type
P122
0 = External Momentary
1 = External Maintained
2 = Internal
Over-Weight Detection Delay Time
P123 180 = (1.80 seconds)
Over-Weight Reset Time
P124 200 = (2.0 seconds)
Standard Over-Weight
Standard Over-Weight (1) Value *Low Speed
C041 14.0 Amps
Standard Over-Weight (2) Value *High Speed
C111 15.0 Amps
Digital Output 11 Function
C021 44:MO1
Digital Output 11 Status
C031 00: N.O
Digital Output 12 Function
C022 52:Reverse Dir
Digital Output 12 Status
C032 01: N.C
Digital Output 12 On Delay
C132 2.0 s