GENERAL WARNINGS & CAUTIONS
1.1 ELECTRICAL WIRING ROUTING
ALL WIRING TO THE SAUNA HEATER AND ACCESSORIES MUST BE ROUTED AWAY FROM ANY DIRECT
RADIATION FROM THE SAUNA HEATER
1.2. WATER SPRAY
NEVER SUBJECT THE SAUNA HEATER OR CONTROL COMPONENTS TO DIRECT WATER SPRAY
1.3. SHOWER HEAD
NEVER INSTALL A SHOWER HEAD ABOVE THE SAUNA HEATER
1.4. FREQUENT HIGH LIMIT SWITCH FAULTS
IF THE MANUALLY RESETTABLE TEMPERATURE-LIMITING CONTROL TRIPS FREQUENTLY, A
QUALIFIED SERVICEMAN SHOULD BE CONTACTED
1.5. FIRE PREVENTION
CAUTION: AVOID A FIRE, DO NOT PLACE COMBUSTIBLE MATERIAL ON SAUNA HEATER
ATTENTION : ÉVITEZ LES INCENDIES, NE PLACEZ AUCUNE MATIÈRE COMBUSTIBLE SUR LE
1.6. APPROVED CONTACTORS
CAUTION: USE ONLY A CONTACTOR APPROVED FOR 250 000 ENDURANCE CYCLES
ATTENTION : UTILISER UNIQUEMENT UN CONTACTEUR APPROUVÉ POUR 250 000 CYCLES DE
1.7. MAINTENANCE PROGRAM
THE OWNER MUST IMPLEMENT A MAINTENANCE PROGRAM FOR THE SAUNA HEATER AND INSPECT
THE SAUNA HEATER AT THE END OF EACH DAY TO ENSURE THE SAUNA HEATER IS TURNED OFF
2. GENERAL SPECIFICATIONS
ELECTRICAL WIRING AND HOOK-UP SHOULD BE DONE BY A CERTIFIED ELECTRICIAN. ELECTRICAL
CONNECTION BY A NON-CERTIFIED PERSON VOIDS THE WARRANTY. NEVER INSTALL ELECTRICAL
WIRING SUCH THAT IT COULD BE EXPOSED TO HEAT RADIATING FROM THE SAUNA HEATER. THE
CONTROL BOX MUST BE INSTALLED ON THE OUTSIDE OF THE SAUNA ROOM. DO NOT INSTALL ANY
ELECTRICAL RECEPTACLES INSIDE THE SAUNA ROOM.
NOTE: NO COMBUSTIBLE MATERIALS ARE PERMITTED UNDER THE HEATER. EXAMPLES OF THIS ARE
DUCKBOARD, TOWELS, PAPER TOWELS, ETC.