46
Align the notch on the starter pulley
with the hole at the top of recoil starter.
FUEL VALVE LEVER
OONN
ON
Remove the sediment cup (see page ), and then turn the fuel
valve lever to the ON position.
Allow the gasoline to drain completely, and then install the sediment
cup (see page ).
Change the engine oil (refer to page ).
Remove the spark plug, and pour about a tablespoon of clean
engine oil into the cylinder. Turn the engine several revolutions
slowly with the recoil starter to distribute the oil, then reinstall the
spark plug.
Slowly pull the starter grip until resistance is felt. At this point, the
piston is coming up on its compression stroke and both the intake
and exhaust valves are closed. Storing the engine in this position
will help to protect it from internal corrosion.