MAINTENANCE
3-10
BATTERY CHECK (CXS TYPE ONLY)
Battery handling differs according to the type of
battery. Refer to the battery manufacturer's
instructions.
Check whether the battery fluid is between the upper
(1) and lower levels (2), and check the vent hole in each
battery cap for clogging.
If the battery fluid is near or below the lower level, add
distilled water to the upper level.
A battery can explode if you do not follow the proper
procedure, causing serious injury to anyone near-
by.
Follow all procedures carefully and keep sparks
and open flames away from the battery.
The battery contains sulfuric acid (electrical) which
is highly corrosive and poisonous.
Getting electrolyte in your eyes or on your skin can
cause serious burns.
Wear protective clothing and eye protection when
working on or a near battery.
Swallowing electrolyte can cause fatal poisoning if
immediate action is not taken.
Battery posts, terminals, and related accessories
contain lead and lead compounds. When your
hands after handling.
(1)
(2)
82Z30000.book 10 ページ 2010年6月25日 金曜日 午後5時50分

Other manuals for Honda EG6500CXS

Questions and Answers:

Honda EG6500CXS Specifications

General IconGeneral
AC Output120/240V
Displacement389 cc
EngineHonda GX390
Rated Power5.5 kVA
Maximum Power6.5 kVA
DC Output12V
Starting SystemElectric