Do you have a question about the Honda EM400 and is the answer not in the manual?
Voltage | 120V |
---|---|
Frequency | 60 Hz |
Fuel Type | Gasoline |
Starting System | Recoil |
Engine Type | Single cylinder |
Operate generator in well-ventilated open spaces, away from confined areas, ensuring proper clearance and exhaust direction.
Keep people, animals, and combustible materials away from the generator and its exhaust.
Handle generator carefully: level surface, no moving while running, safe refueling, no overfilling, service when off, avoid wet hands/weather.
Do not connect to household wiring; ensure adequate cooling and safe ambient temperatures.
Identifies key controls and receptacles on the front panel of the EM400 generator.
Identifies key covers and outlets located on the rear of the EM400 generator.
Check fuel level, note tank capacity, and understand total operating time with a full tank.
Properly check engine oil level using the dipstick on a level surface.
Select appropriate oil viscosity and understand AC-DC selector switch operation for different modes.
Follow the outlined steps for moving the control lever and pulling the starter grip.
Steps to take if the engine fails to start after multiple attempts, including checking connections and spark plug.
Steps for connecting appliances to the AC output receptacle, ensuring the engine is running and the switch is set to AC.
Steps for charging a 12V battery using the DC output, ensuring correct polarity and connections.
Understand the function of the DC pilot lamp and troubleshooting if it does not light.
Covers changing engine oil, servicing spark plugs, and maintaining breaker points for optimal performance.
Procedures for cleaning the air cleaner and spark arrestor to ensure proper operation and emissions.
Lubrication steps for the recoil starter to ensure smooth operation.
Guidance on fuse replacement and troubleshooting for the generator's electrical components.