Section 3: Programming the 7847i-E
3-3
PROMPTS ENTRY OPTIONS DESCRIPTION
then press the [Enter] key when prompted for the new
password and its confirmation.
6
Enter Password
[0-9, A-F, N, S,
T, X, Y]
This prompt is displayed if [Y] was pressed in Prompt 4 or
5.
Enter a 4-digit password (0-9, A-F, N, S, T, X, Y).
7
Verify Password
[0-9, A-F, N, S,
T, X, Y]
Re-enter the password as confirmation.
If the password doesn't match the first entry, the following
is displayed followed by the "Exit Prog. Mode?" prompt:
Verify Not OK
PSWD not created
Otherwise, the "Exit Prog. Mode?" prompt is displayed
directly.
8
Exit Prog. Mode?
(Y/N)_
[Y], [N]
[ESC]
Exits program mode.
Press [N] to go back to Prompt 3.
Press [ESC] to load factory defaults.
Refer to the Exiting Programming Mode paragraph in this
section.
9
Device Mode
(ECP)_
ECP
Zone Triggers
4204 Emu
Two 4204s
Press the [space] key to scroll through the modes of
operation. Press [ENTER] to select ECP mode.
See Table 5 if programming other modes.
10
CS IP:
255.255.255.255
12 digit:
xxx.xxx.xxx.xxx
Enter the four part primary CS IP address of the receiver
at the reporting center to which this device will report.
The four parts of the address must be separated by
spaces.
NOTE: This entry CANNOT be left a
s 255.255.255.255”. It
MUST be programmed with a valid IP address.
11
CS Port:
(80)
[80] Enter the Central Station Port Number.
NOTE: The CS Port number must match the "Listening
Port" question of the receiver.
12
Alarm Delivery:
Only One CS IP_
[Only One CS IP]
[Fail to CS IP2]
Select the "Only One CS IP" option, if only one Central
Station IP address is desired and go to Prompt 18: Verify
Inst. Key. Select the "Fail to CS IP2" option, if a
secondary Central Station IP address is desired.
13
Secondary CS IP:
255.255.255.255
12 digit:
xxx.xxx.xxx.xxx
Prompts 13-15 apply only if Prompt 12: Alarm Delivery is
set to “Fail to CS IP2".
Enter the four part secondary CS IP address of the receiver
at the reporting center to which this device will report. The
four parts of the address must be separated by spaces.
NOTE: This entry CANNOT be left as “255.255.255.255” if
using the Secondary CS IP. It MUST be programmed with
a valid IP address.
14
Second CS Port:
(80)
[80]
Enter the Central Station Port Number.
NOTE: The CS Port number must match the "Listening
Port" question of the receiver.
15
IP2 Supervision
30 Day_
30 Day
Daily
Full Rate
None
Sets the supervision timing for the secondary internet
receiver to send a test alarm if set to Daily or 30 Day, or
to send a status message to the receiver if the interval is
set to Full Rate. Selecting Full Rate means secondary
supervision will be the same as primary.
NOTE: The second receiver
must be programmed to
supervise subscribers in order to generate a
communication failure.
Press the [space] key to scroll through the choices.