Program Sector (Honeywell VCL and Supported 3rd Party
Protocols)
This menu option is only displayed when the ACUIX DIP switches are set to Honeywell VCL,
Pelco P, or Pelco D protocol. When set to Honeywell Standard mode, this option is NA (not
applicable). See Program Sector IDs, page 49, in Chapter 3, Operation and Programming
with Honeywell Diamond Protocol for more information on programming Sectors.
1. Select 5 to program a Sector. Move the joystick down until 5 is highlighted and then
press Iris Open.
2. Move the joystick up until the desired Sector ID number (116) displays. Move the
joystick left and right to move between the digits, if necessary.
3. Press Iris Open.
4. Move the joystick up or down to enter a 24-alphanumeric name for the Sector. This
name displays on the video whenever the ACUIX is viewing any portion of the
programmed Sector. Move the joystick left or right to position the cursor.
5. When the desired name displays, press Iris Open.
6. Press Focus Near to go to PTZ mode.
7. Position the video to the lower left corner of the Sector.
8. Press Focus Far to return to the programming menu.
9. Press Iris Open.
10. Press Focus Near to go to PTZ mode.
11. Position the video to the upper right corner of the Sector.
12. Press Focus Far to return to the programming menu.
13. Press Iris Open. If the upper right tilt position is below the lower left tilt position, the
message Illegal Tilt Direction displays. Repeat steps 510 or press
Clear/Manual to cancel the operation and return to manual operation.
14. Program another Sector ID or press Iris Close to exit programming.
Program Privacy Zone (Honeywell VCL and Supported 3rd
Party Protocols)
This menu option is only displayed when the ACUIX DIP switches are set to Honeywell VCL,
Pelco P, or Pelco D protocol. When set to Honeywell Standard mode, this option is NA (not
applicable). See Privacy Zones, page 51, in Chapter 3, Operation and Programming with
Honeywell Diamond Protocol for more information on programming Privacy Zones.
Note Upon powering up, the ACUIX dome will automatically find home so the
dome can then run Presets and so on as they were programmed. If a Privacy
Zone is enabled, no video will be shown during homing, as your Privacy
Zones are not recognized until ACUIX has reached home. Video will display
once the dome has reached its home setting, unless a Privacy Zone overlaps
with the home setting.