136
Specifications
Operating/Programming Specifications
• Remote firmware download via IntelliBus™ protocol:
• Download firmware from PC to Dome
• Remote upload/download of configuration data
• Fast setup with remote upload of all Preset and Tour information to replacement
camera via IntelliBus™ protocol
• Presets—protocol dependent:
• Diamond—148 user-defined Presets (0–70, 80–97, 100–160)
• VCL—97 user-defined Presets (0–70, 100–127)
• Freeze frame between Presets
• 24-character label for each Preset
• 16 Preset Tours of up to 64 Presets each
• 16 Mimic Tours, up to 2 minutes each, for a total of 32 minutes of Mimic Tours
• Patented Flashback function allows for quick recall of the previous set scene
• 32 total Privacy Zones; 8 can be simultaneously active
• 16 zones (programmable in size); can be labeled with up to 24 characters each
• Programmable locations of labels and on-screen displays
• Camera title overlay, 24 user-definable characters
• On-screen pan/tilt/zoom coordinate display
• 3 programmable actions after a user-defined period of non-activity:
• Camera will go to a Preset location chosen by the user
• Camera will call a Preset Tour chosen by the user
• Camera will call a Mimic Tour chosen by the user
• Password protection—on-screen displays only—1 user (supervisor)
• Data line polarity detection for standard protocol
• 4 alarm inputs
• PASS function—continually alters pan and tilt speeds in proportion to the depth of
the zoom
• Auto flip rotates the dome 180° at the bottom of tilt travel
• Remote address, protocol, baud rate, and parity selection (enabled via DIP switch)
• Diagnostic information is available locally and via remote access
• Multi-language menus (Chinese, English, French, German, Italian, Portuguese and
Spanish)
• Supports all Honeywell protocols: IntelliBus™, Diamond, VCL protocols and
MAXPRO mode
• Emulates Pelco P and D protocols