Operation and Programming with Honeywell Diamond Protocol
a. Press + or - until the desired character displays on the LCD screen, and then
press Character Select. The controller sends the character to the ACUIX.
b. Continue selecting characters and pressing Character Select until the desired
title displays on the monitor.
c. Press Enter. The cursor moves to the first Preset field.
8. Enter the first Preset number (070, 8097, or 100160) using the numeric keys.
Note If the cursor doesn’t automatically move to the Velocity field, press the right
arrow key below the controller’s LCD.
9. Enter the velocity from 1 to 480 (degrees per second) in the VELOCITY column of the
0 row. If the cursor doesn’t automatically move to the Velocity field, press the right
arrow key below the controller’s LCD.
10. Enter the Dwell Time from 099 seconds.
11. Continue entering Presets (up to a total of 64) by repeating steps 8, 9, and 10.
12. Press Enter when finished adding Presets. The following commands are displayed on
the bottom of the monitor.
13. Program another Preset Tour or press Clear/Manual to exit the VectorScan
Programming menu.
14. Press Dome Menu or press ESC three times to exit the menus on the controller LCD.
Table 3-8 Preset Tour Commands
Command Function
E = Edit Press + or - key until E displays on the LCD and press Character
Select, then repeat steps 811.
D = Delete Press + or - key until D displays on the LCD and press Character
Select. The Preset Tour number entered in step 6 is deleted.
S = Save Press + or - key until S displays on the LCD and press Character
Select. The programming entered for the Preset Tour number
entered in step 6 is saved.